MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1093/ehjcr/ytz125

Медицинская библиотека · European heart journal. Case reports · 2019

A case report: use of cerebral oximetry in the early detection of cerebral hypoperfusion in a post-cardiac arrest patient during targeted temperature management.

Ng Shonda, Chia Yew Woon

Клинический случайСтатьяПеревод в очереди

Аннотация

BACKGROUND

We present a patient who received cerebral oximetry monitoring during targeted temperature management (TTM) post-cardiac arrest and discuss its potential in the early detection of cerebral hypoperfusion and implications on haemodynamics and ventilatory management.

CASE SUMMARY: A 60-year-old Chinese male was admitted for acute pulmonary oedema with Type 2 respiratory failure. He failed an initial trial of non-invasive ventilation and was planned for intubation and mechanical ventilation. However, the patient suffered a pulseless electrical activity cardiac arrest peri-intubation. He was started on our institution's protocolized post-cardiac arrest care bundle, which included cerebral regional oxygen saturation (rSO2) monitoring and TTM. Initial arterial blood gas (ABG) post-return of spontaneous circulation showed severe respiratory acidosis, and the patient was sedated, paralyzed, and ventilator settings optimized. Repeat ABG showed resolution of respiratory acidosis. However, a drop in rSO2 to 35% was subsequently noted. Ventilator settings were quickly adjusted, and dobutamine was started to improve global and cerebral perfusion. These measures improved cerebral rSO2 to more than 50%. Patient was cooled for 24 h and gradually rewarmed. He was later extubated with a cerebral performance category of 1 and is now on outpatient follow-up.

DISCUSSION: During post-cardiac arrest care, there are many factors which can contribute to a decrease in cerebral blood flow. Therapeutic hypothermia and ventilation strategies, including the use of neuromuscular blocking agents, can both reduce pCO2 which is a major regulator of cerebrovascular tone. Accidental hypocapnia can lead to adverse cerebral vasoconstriction and hypoperfusion. Without cerebral oximetry, cerebral ischaemia may not be detected early and can potentially result in secondary brain injury.

Для цитирования: Ng Shonda, Chia Yew Woon. A case report: use of cerebral oximetry in the early detection of cerebral hypoperfusion in a post-cardiac arrest patient during targeted temperature management.. European heart journal. Case reports. 2019. DOI: 10.1093/ehjcr/ytz125.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.