Investigative ophthalmology & visual science · 2019
Optical Coherence Tomography Angiography in Mice: Quantitative Analysis After Experimental Models of Retinal Damage.
СтатьяПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Smith Corey A, Hooper Michele L, Chauhan Balwantray C
Аннотация
PURPOSE: We implemented optical coherence tomography angiography (OCT-A) in mice to: (1) develop quantitative parameters from OCT-A images, (2) measure the reproducibility of the parameters, and (3) determine the impact of experimental models of inner and outer retinal damage on OCT-A findings.
METHODS: OCT-A images were acquired with a customized system (Spectralis Multiline OCT2). To assess reproducibility, imaging was performed five times over 1 month. Inner retinal damage was induced with optic nerve transection, crush, or intravitreal N-methyl-d-aspartic acid injection in transgenic mice with fluorescently labeled retinal ganglion cells (RGCs). Light-induced retinal damage was induced in albino mice. Mice were imaged at baseline and serially post injury. Perfusion density, vessel length, and branch points were computed from OCT-A images of the superficial, intermediate, and deep vascular plexuses.
RESULTS: The range of relative differences measured between sessions across the vascular plexuses were: perfusion density (2.8%-7.0%), vessel length (1.9%-4.1%), and branch points (1.9%-5.0%). In mice with progressive RGC loss, imaged serially and culminating in around 70% loss in the fluorescence signal and 18% loss in inner retinal thickness, there were no measurable changes in any OCT-A parameter up to 4 months post injury that exceeded measurement variability. However, light-induced retinal damage elicited a progressive loss of the deep vascular plexus signal, starting as early as 3 days post injury.
CONCLUSIONS: Vessel length and branch points were generally the most reproducible among the parameters. Injury causing RGC loss in mice did not elicit an early change in the OCT-A signal.
METHODS: OCT-A images were acquired with a customized system (Spectralis Multiline OCT2). To assess reproducibility, imaging was performed five times over 1 month. Inner retinal damage was induced with optic nerve transection, crush, or intravitreal N-methyl-d-aspartic acid injection in transgenic mice with fluorescently labeled retinal ganglion cells (RGCs). Light-induced retinal damage was induced in albino mice. Mice were imaged at baseline and serially post injury. Perfusion density, vessel length, and branch points were computed from OCT-A images of the superficial, intermediate, and deep vascular plexuses.
RESULTS: The range of relative differences measured between sessions across the vascular plexuses were: perfusion density (2.8%-7.0%), vessel length (1.9%-4.1%), and branch points (1.9%-5.0%). In mice with progressive RGC loss, imaged serially and culminating in around 70% loss in the fluorescence signal and 18% loss in inner retinal thickness, there were no measurable changes in any OCT-A parameter up to 4 months post injury that exceeded measurement variability. However, light-induced retinal damage elicited a progressive loss of the deep vascular plexus signal, starting as early as 3 days post injury.
CONCLUSIONS: Vessel length and branch points were generally the most reproducible among the parameters. Injury causing RGC loss in mice did not elicit an early change in the OCT-A signal.
Предметные рубрики MeSH
AnimalsFemaleFluorescein AngiographyIntravitreal InjectionsLightMaleMiceMice, Inbred BALB CMice, Inbred C57BLMice, TransgenicModels, AnimalN-MethylaspartateNerve CrushOptic Nerve InjuriesRadiation Injuries, ExperimentalReproducibility of ResultsRetinaRetinal DiseasesRetinal Ganglion CellsRetinal VesselsTomography, Optical Coherence