MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/aor.14743

Медицинская библиотека · Artificial organs · 2024

Preclinical validation of a customized circuit for ex situ uninterrupted cold-to-warm prolonged perfusion of the liver.

Scatton Olivier, Turco Célia, Savier Eric, Pelissié Jérôme, Legallais Cécile, Sakka Medhi, Aoudjehane Lynda, Wendum Dominique, Migliazza John, Spiritelli Sandra, Conti Filomena, Goumard Claire

СтатьяВалидационное исследованиеПеревод в очереди

Аннотация

CONTEXT: Clinical adoption of ex situ liver perfusion is growing. While hypothermic perfusion protects against ischemia-reperfusion injury in marginal grafts, normothermic perfusion enables organ viability assessment and therefore selection of borderline grafts. The combination of hypothermic and normothermic perfusion, known as "cold-to-warm," may be the optimal sequence for organ preservation, but is difficult to achieve with most commercial perfusion systems. We developed an adaptable customized circuit allowing uninterrupted "cold-to-warm" perfusion and conducted preclinical studies on healthy porcine livers and discarded human livers to demonstrate the circuit's efficacy.

METHODS

In collaboration with bioengineers, we developed a customized circuit that adapts to extracorporeal circulation consoles used in cardiovascular surgery and includes a proprietary reservoir enabling easy perfusate change without interrupting perfusion. This preclinical study was conducted on porcine and human livers. Perfusion parameters (pressures, flows, oxygenation) and organ viability were monitored.

RESULTS

The customized circuit was adapted to a LivaNova S5® console, and the perfusions were flow-driven with real-time pressure monitoring. Ten porcine liver and 12 discarded human liver perfusions were performed during 14 to 18 h and 7 to 25 h, respectively. No hyperpressure was observed (porcine and human portal pressure 2-6 and 2-8 mm Hg; arterial pressure 10-65 and 20-65 mm Hg, respectively). No severe histological tissue injury was observed (Suzuki score ≤ 3 at the end of perfusion). Seven (70%) porcine livers and five (42%) human livers met the UK viability criteria.

CONCLUSION

The customized circuit and system design enables smooth uninterrupted "cold-to-warm" perfusion not present in current commercial perfusion systems.

Для цитирования: Scatton Olivier, Turco Célia, Savier Eric, Pelissié Jérôme, Legallais Cécile, Sakka Medhi, Aoudjehane Lynda, Wendum Dominique, Migliazza John, Spiritelli Sandra, Conti Filomena, Goumard Claire. Preclinical validation of a customized circuit for ex situ uninterrupted cold-to-warm prolonged perfusion of the liver.. Artificial organs. 2024. DOI: 10.1111/aor.14743.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.