m+Medelevator.RU
← Поиск публикаций
Journal of the Egyptian National Cancer Institute · 2026

Use of indocyanine green fluorescence versus patent blue V dye for sentinel lymph node biopsy in early breast cancer, a randomized controlled trial.

СтатьяРандомизированное исследованиеСравнительное исследованиеНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Nida Muhammad, Abdelmoghny Ashraf, Osman Ahmed G, Abd-erRazik Mohammad A, Hanafy Dina M

Аннотация

BACKGROUND: Sentinel lymph node biopsy (SLNB) is standard for axillary staging in early breast cancer. While the combination of radioisotope and blue dye (e.g., patent blue V, PBV) remains the standard, it has limitations including logistics, variable identification rate (IR), and allergic potential. Indocyanine green (ICG) fluorescence is a promising alternative, but high-quality comparative evidence is needed.

METHODS: This was a single-center, prospective, randomized controlled trial. Forty patients with early-stage, node-negative breast cancer were allocated to SLNB using either ICG (n = 20) or PBV (n = 20). All patients subsequently underwent completion level I-II axillary lymph node dissection (ALND) as the pathological reference standard for diagnostic performance assessment. Primary outcome was sentinel lymph node (SLN) IR. Secondary outcomes included detection time, number of SLNs retrieved, false-negative rate (FNR), and safety.

RESULTS: Baseline characteristics were comparable between groups. The SLN IR was significantly higher with ICG (100% [20/20]) than with PBV (75% [15/20], p = 0.047). ICG was associated with a significantly shorter median detection time (14.5 vs. 24.0 min, p < 0.001) and retrieved more SLNs (mean: 3.6 vs. 2.4, p = 0.002). Most critically, ICG demonstrated 100% sensitivity, specificity, negative predictive value (NPV), and overall diagnostic accuracy, with a 0% FNR. In contrast, PBV achieved a sensitivity of 75%, an overall diagnostic accuracy of 90%, and an FNR of 25%. No ICG-related adverse events occurred. PBV caused skin discoloration in 75% of patients and one (5%) allergic reaction.

CONCLUSION: ICG fluorescence achieved a higher SLN IR, shorter detection time, higher sensitivity, lower FNR, and fewer tracer-related adverse events than PBV as a single tracer for SLNB in patients with early-stage breast cancer. These findings suggest that ICG is a promising standalone tracer when radioisotope mapping is unavailable. Larger multicenter studies are required before widespread adoption can be recommended.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты