MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.ijrobp.2006.03.035

Медицинская библиотека · International journal of radiation oncology, biology, physics · 2006

Impact of geometrical uncertainties on 3D CRT and IMRT dose distributions for lung cancer treatment.

Schwarz Marco, Van der Geer Joris, Van Herk Marcel, Lebesque Joos V, Mijnheer Ben J, Damen Eugène M F

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

PURPOSE: To quantify the effect of set-up errors and respiratory motion on dose distributions for non-small cell lung cancer (NSCLC) treatment.

METHODS AND MATERIALS: Irradiations of 5 NSCLC patients were planned with 3 techniques, two (conformal radiation therapy (CRT) and intensity modulated radiation therapy (IMRT1)) with a homogeneous dose in the planning target volume (PTV) and a third (IMRT2) with dose heterogeneity. Set-up errors were simulated for gross target volume (GTV) and organs at risk (OARs). For the GTV, the respiration was also simulated with a periodical motion around a varying average. Two configurations were studied for the breathing motion, to describe the situations of free-breathing (FB) and respiration-correlated (RC) CT scans, each with 2 amplitudes (5 and 10 mm), thus resulting in 4 scenarios (FB_5, FB_10, RC_5 and RC_10). Five thousand treatment courses were simulated, producing probability distributions for the dosimetric parameters.

RESULTS

For CRT and IMRT1, RC_5, RC_10 and FB_5 were associated with a small degradation of the GTV coverage. IMRT2 with FB_10 showed the largest deterioration of the GTV dosimetric indices, reaching 7% for Dmin at the 95% probability level. Removing the systematic error due to the periodic breathing motion was advantageous for a 10 mm respiration amplitude. The estimated probability of radiation pneumonitis and acute complication for the esophagus showed limited sensitivity to geometrical uncertainties. Dmax in the spinal cord and the parameters predicting the risk of late esophageal toxicity were associated to a probability up to 50% of violating the dose tolerances.

CONCLUSIONS

Simulating the effect of geometrical uncertainties on the individual patient plan should become part of the standard pre-treatment verification procedure.

Для цитирования: Schwarz Marco, Van der Geer Joris, Van Herk Marcel, Lebesque Joos V, Mijnheer Ben J, Damen Eugène M F. Impact of geometrical uncertainties on 3D CRT and IMRT dose distributions for lung cancer treatment.. International journal of radiation oncology, biology, physics. 2006. DOI: 10.1016/j.ijrobp.2006.03.035.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.