MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1159/000357430

Медицинская библиотека · Fetal diagnosis and therapy · 2013

First-trimester screening for trisomies 21, 18 and 13 by ultrasound and biochemical testing.

Wright D, Syngelaki A, Bradbury I, Akolekar R, Nicolaides K H

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

OBJECTIVE

To examine the performance of screening for trisomies 21, 18 and 13 at 11-13 weeks' gestation using specific algorithms for these trisomies based on combinations of fetal nuchal translucency thickness (NT), fetal heart rate (FHR), ductus venosus pulsatility index for veins (DV PIV), and serum free β-human chorionic gonadotropin (β-hCG), pregnancy-associated plasma protein A (PAPP-A), placental growth factor (PLGF) and α-fetoprotein (AFP).

METHODS

Model-based estimates of screening performance were produced for the distribution of maternal ages in England and Wales in 2011, and prospectively collected data on fetal NT, FHR, DV PIV, β-hCG, PAPP-A, PLGF and AFP from singleton pregnancies undergoing aneuploidy screening.

RESULTS

In screening by NT, FHR, free β-hCG and PAPP-A, using specific algorithms for trisomy 21 and trisomies 18 and 13 at the risk cutoff of 1:100, the estimated detection rate (DR) was 87.0% for trisomy 21 and 91.8% for trisomies 18 and 13, at a false-positive rate (FPR) of 2.2%. Addition of PLGF, AFP and DV PIV increased the DR to 93.3% for trisomy 21 and 95.4% for trisomies 18 and 13 and reduced the FPR to 1.3%.

CONCLUSIONS

Effective screening for trisomies can be achieved using specific algorithms based on NT, FHR, DV PIV, β-hCG, PAPP-A, PLGF and AFP.

Для цитирования: Wright D, Syngelaki A, Bradbury I, Akolekar R, Nicolaides K H. First-trimester screening for trisomies 21, 18 and 13 by ultrasound and biochemical testing.. Fetal diagnosis and therapy. 2013. DOI: 10.1159/000357430.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.