DOI 10.1002/rcm.3319

Медицинская библиотека · Rapid communications in mass spectrometry : RCM · 2007

Simple and sensitive quantification of bioactive peptides in biological matrices using liquid chromatography/selected reaction monitoring mass spectrometry coupled with trichloroacetic acid clean-up.

Murao Naoaki, Ishigai Masaki, Yasuno Hideyuki, Shimonaka Yasushi, Aso Yoshinori

СтатьяВалидационное исследованиеПеревод в очереди

Аннотация

A simple and sensitive liquid chromatography/electrospray ionization tandem mass spectrometric (LC/ESI-MS/MS) method has been developed for the quantification of bioactive peptides in biological fluids. The method employs protein precipitation with 4% trichloroacetic acid (TCA) and selected reaction monitoring (SRM) using an immonium ion as the product ion. This method was applied to determine the synthetic parathyroid hormone (PTH) analog (MW 1721) in rat plasma and human hepcidin-25 (MW 2789) in human serum. TCA clean-up showed a sufficient recovery for peptides with a MW of less than 3000, and would be useful as a simple and rapid method because of direct injection of the supernatant without evaporation or dilution. In addition, TCA clean-up allowed us not only to reduce sample preparation time, but also to select an immonium ion as a product ion of SRM, which led to detection more sensitive than SRM using other types of product ions. The lower limits of quantitation (LLOQs) of the PTH analog and the human hepcidin-25 were 0.2 ng/mL and 5 ng/mL, respectively. This method was fully validated with acceptable linearity, intra- and inter-assay precisions, and accuracy. Furthermore, this simple and rapid method is applicable to pharmacokinetic studies.

Для цитирования: Murao Naoaki, Ishigai Masaki, Yasuno Hideyuki, Shimonaka Yasushi, Aso Yoshinori. Simple and sensitive quantification of bioactive peptides in biological matrices using liquid chromatography/selected reaction monitoring mass spectrometry coupled with trichloroacetic acid clean-up.. Rapid communications in mass spectrometry : RCM. 2007. DOI: 10.1002/rcm.3319.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.