MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.cardfail.2020.06.010

Медицинская библиотека · Journal of cardiac failure · 2020

Elevated AT1R Antibody and Morbidity in Patients Bridged to Heart Transplant Using Continuous Flow Left Ventricular Assist Devices.

Chau Vinh Q, Flattery Maureen, Nicholson Kate S, Mcdougan Felecia, Gupta Gaurav, Uber Patricia, Priday Anna G, Desai Kevin, Kimball Pamela M, Shah Keyur B

СтатьяПеревод в очереди

Аннотация

BACKGROUND

We studied longitudinal levels of angiotensin-II type 1 receptor antibody (AT1R-Ab) and their effects on adverse events (death, treated rejection and cardiac allograft vasculopathy) in patients who were bridged to heart transplant using a continuous flow left ventricular assist device (LVAD).

METHODS AND

RESULTS

Sera of 77 patients bridged to heart transplant (from 2009 to 2017) were tested for AT1R-Ab and CRP before and after LVAD. Elevated AT1R-Ab was defined as >10.0 U/mL. The median follow-up after transplant was 3.6 years (interquartile range, 2.2-5.6 years). After LVAD, AT1R-Ab levels increased from baseline and remained elevated until transplant. Freedom from adverse events at 5 years was lower in those with elevated AT1R-Ab levels at time of transplant. In an adjusted, multivariable Cox analysis, an AT1R-Ab level of >10 U/mL was associated with developing the primary end point (adjusted hazard ratio 3.4, 95% confidence interval 1.2-9.2, P = .017). Although C-reactive protein levels were high before and after LVAD placement, C-reactive protein did not correlate with AT1R-Ab.

CONCLUSIONS

In LVAD patients bridged to heart transplant, an increased AT1R-Ab level at time of transplant was associated with poor outcomes after heart transplant. Post-LVAD AT1R-Ab elevations were not correlated with serum markers of systemic inflammation. Larger studies are needed to examine the pathologic role of AT1R-Ab in heart transplant.

Для цитирования: Chau Vinh Q, Flattery Maureen, Nicholson Kate S, Mcdougan Felecia, Gupta Gaurav, Uber Patricia, Priday Anna G, Desai Kevin, Kimball Pamela M, Shah Keyur B. Elevated AT1R Antibody and Morbidity in Patients Bridged to Heart Transplant Using Continuous Flow Left Ventricular Assist Devices.. Journal of cardiac failure. 2020. DOI: 10.1016/j.cardfail.2020.06.010.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.