MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jvir.2017.04.024

Медицинская библиотека · Journal of vascular and interventional radiology : JVIR · 2017

Complication Rates Observed in Silicone and Polyurethane Catheters of Totally Implanted Central Venous Access Devices Implanted in the Upper Arm.

Busch Jasmin D, Vens Maren, Mahler Catherine, Herrmann Jochen, Adam Gerhard, Ittrich Harald

СтатьяПеревод в очереди

Аннотация

PURPOSE: To present frequency and types of complications related to silicone (SI) versus polyurethane (PUR) catheters of totally implanted venous access devices (TIVADs) placed in the upper arm.

MATERIAL AND

METHODS

A cohort of 2,491 consecutive patients with TIVADs implanted between 2006 and 2015 was retrospectively analyzed. Complications were classified according to SIR guidelines. Pearson χ2 test was used for categorical variables, and Student t test was used for continuous variables. Nominal P values were reported, and 2-sided P values < .05 were considered significant.

RESULTS

Of 2,270 patients meeting the inclusion criteria, 538 had an SI catheter, and 1,732 had a PUR catheter. Total dwell time was 584,853 catheter days. Mean total complication rate was 12.25% (SI, 14.87%; PUR, 11.43%; P = .040). Subanalysis revealed significant differences for material failures (eg, catheter fracture [SI, 3.35%; PUR, 0.06%; P < .001] and thrombotic catheter occlusion/venous thromboses [SI, 2.79%/0.74%; PUR, 1.33%/3.17%; P < .001]) but nonsignificant differences for infections (eg, local infection and catheter-related sepsis [SI, 4.64%; PUR, 4.68%; P = 1]) or other nonthrombotic dysfunctions (eg, catheter detachment, line migration, wound dehiscence [SI, 3.35%; PUR, 2.19%; P = .179]).

CONCLUSIONS

The reported data suggest different risk profiles in SI catheters compared with PUR catheters, with more material failures and thrombotic catheter occlusions in SI catheters and more venous thromboses in PUR catheters.

Для цитирования: Busch Jasmin D, Vens Maren, Mahler Catherine, Herrmann Jochen, Adam Gerhard, Ittrich Harald. Complication Rates Observed in Silicone and Polyurethane Catheters of Totally Implanted Central Venous Access Devices Implanted in the Upper Arm.. Journal of vascular and interventional radiology : JVIR. 2017. DOI: 10.1016/j.jvir.2017.04.024.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.