m+Medelevator.RU
← Поиск публикаций
Journal of chromatography. B, Analytical technologies in the biomedical and life sciences · 2026

Enhanced selectivity for PFAS analysis in complex biological matrices by LC-MS/MS: Application to mouse feces and liver.

СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Zhang Gong, Blais Amélie, Tayabali Azam F, Pelletier Guillaume, Loan Allison, Prescott David, Eccles Kristin M, Aranda-Rodriguez Rocio

Аннотация

A sensitive and robust micro-solid phase extraction LC-tandem mass spectrometry (μSPE-LC-MS/MS) method was established for quantifying 23 per- and polyfluoroalkyl substances (PFAS) in mouse feces and liver. Method development identified interferences due to the complex fecal matrix, especially at unit-mass resolution detection, where co-eluting endogenous compounds caused transition-specific interferences. Conventional C18 stationary phases failed to adequately resolve these matrix components, particularly for perfluoroalkyl sulfonic acids (PFSAs), resulting in compromised selectivity. To reduce these matrix effects, alternative stationary phases, including Phenyl-Hexyl (Phe) and Pentafluorophenyl (PFP) columns, were systematically evaluated. The PFP column, operated with acetonitrile in the mobile phase, demonstrated superior chromatographic selectivity and effectively eliminated co-eluting interferences. Notably, transition-specific interferences previously observed for PFOS on C18 columns were resolved, allowing accurate quantification using both m/z 499 → 80 and 499 → 99 transitions. Using the improved selectivity of the PFP column, automated μSPE cleanup combined with isotope-labelled internal standards achieved high extraction efficiencies (96-104%), ensuring reliable accuracy and precision (recoveries 96-99%, RSD <5%) for most analytes despite matrix complexity. These findings demonstrate the importance of chromatographic selectivity, rigorous cleanup, and isotopic correction for quantifying PFAS in highly complex biological matrices using unit-resolution mass spectrometry. The developed workflow provides a reliable analytical platform for toxicokinetic studies and may be applicable to other challenging biological matrices.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты