DOI 10.1080/10255842.2023.2189993
Open-sourced semi-automatic program for ultrasound assessments of femoral trochlea cartilage health.
Аннотация
We developed an open-sourced program that accounts for the current limitations of B-mode ultrasound and extends the clinical utility of ultrasound for assessing femoral trochlear cartilage thickness. Images were collected on 18 patients with a history of knee surgery. By failing to account for ultrasound acoustics and beam refraction, cartilage thickness was underestimated by 26% and overestimated by 0-4%, respectively (p < 0.001). Comprehensive thickness measurements achieved by measuring the Euclidean distance between every point were significantly different than traditional single-location measurements or by using the area/length (p = 0.004-0.006). Sub-regions were significantly different than all whole regions of interest (p = 0.001-0.012).