MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/scs.0000000000006669

Медицинская библиотека · The Journal of craniofacial surgery · 2020

Evaluation of Lacrimal Drainage Function in the Anophthalmic Socket by Dacryoscintigraphy.

Yildiz Aysegul Mavi, Sendul Selam Yekta, Karapapak Murat, Yildiz Ali Atakhan, Guven Dilek

СтатьяПеревод в очереди

Аннотация

PURPOSE: To investigate whether impaired lacrimal pump function is a possible cause of discharge in patients wearing an artificial eye compared with the remaining healthy eye.

METHODS

Consecutive patients wearing unilateral ocular prosthesis for ≥6 months were included in this retrospective study. Excluded were any deformities of eyelids or nasal passage, socket complications such as entropion, ectropion, ptosis, infection, pyogenic granuloma, contracted socket, obstruction of nasolacrimal duct diagnosed with lacrimal irrigation and a difference greater than 2 mm in terms of protrusion between two eyes detected by Hertel exophthalmometry. Patients were asked to score the levels of tearing and mucopurulent discharge between 0 and 5 to assess lacrimal drainage function subjectively. Furthermore, dacryoscintigraphy was performed to assess the functional status of the lacrimal system objectively.

RESULTS

Included were 32 subjects (12 females, 20 males; aged 32.94 ± 17.62, range 13-78). Mean duration of prosthetic wearing 26.41 ± 21.30 (6-72) months. The mean subjective scores of tearing and mucopurulent discharge were 1.56 ± 1.67 and 1.94 ± 1.63, respectively. The rate of functional stenosis was significantly higher in the anophthalmic socket side as compared to the healthy side (P = 0.002). The rates of a presac, preduct, and intraduct obstruction was notes as n = 9, n = 10, n = 1 and n = 0, n = 6, n = 2 in the anophthalmic side and the companion eye, respectively (P = 0.021).

CONCLUSION

Compared to paired healthy eyes, the ocular prosthesis exhibited significantly higher rates of functional lacrimal duct obstruction, especially at the presac level. The alterations in orbital volume and tear film composition in addition to reduced corneal reflex blinking may lead to the failure of lacrimal pump function in artificial eyes.

Для цитирования: Yildiz Aysegul Mavi, Sendul Selam Yekta, Karapapak Murat, Yildiz Ali Atakhan, Guven Dilek. Evaluation of Lacrimal Drainage Function in the Anophthalmic Socket by Dacryoscintigraphy.. The Journal of craniofacial surgery. 2020. DOI: 10.1097/scs.0000000000006669.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.