OBJECTIVE

The overall goal of this study was to design, fabricate, and characterize a new polymer-based multielectrode for the spinal cord for the application of intraspinal microstimulation (ISMS).

METHODS

Three-channel multielectrodes were fabricated from modified poly(dimethylsiloxane) (PDMS) and platinum-iridium (Pt-Ir) foil using nanosecond laser microfabrication techniques. These devices were compared against traditional 50 μm diameter Pt-Ir microwire electrodes mechanically and electrochemically in bench environments, and were assessed electrochemically and functionally in vivo in a domestic pig model.

RESULTS

Polymer-based multielectrodes were significantly more flexible than microwire electrodes (p < 0.05) and had greater charge storage capacities in phosphate buffered saline (p < 0.05). In a domestic pig model, multielectrodes had significantly greater charge injection limits than microwire electrodes (p < 0.05). When stimulating within the quadriceps motor pool in the spinal cord, multielectrodes generated strong knee extensor joint torques of up to 4.4 ± 0.3 Nm and were able to extend the knee by up to 26 ± 1°. However, histological analyses showed that polymer-based multielectrodes, implanted with half-needle insertion aids, produced greater acute tissue damage compared to microwire electrodes (p < 0.05). Alternative insertion methods for these flexible electrodes should be explored to reduce acute tissue damage.

CONCLUSION

The PDMS-based three-channel multielectrodes demonstrated improved flexibility and charge injection capabilities over traditional microwire electrodes, and were able to produce functional responses in vivo.

SIGNIFICANCE: Polymer-based multielectrodes demonstrate improved functionality over microwire electrodes while remaining more flexible than silicon multielectrode designs. These features may in the future permit polymer-based multielectrodes to implement ISMS with greater efficacy and biocompatibility compared to traditional technologies.

Для цитирования: Roszko David A, Mirkiani Soroush, Tyreman Neil, Wilson Don, Toossi Amirali, Mushahwar Vivian K. Laser-Microfabricated Polymer Multielectrodes for Intraspinal Microstimulation.. IEEE transactions on bio-medical engineering. 2022. DOI: 10.1109/tbme.2022.3191437.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.