MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/jog.13366

Медицинская библиотека · The journal of obstetrics and gynaecology research · 2017

Combined value of placental alpha microglobulin-1 detection and cervical length via transvaginal ultrasound in the diagnosis of preterm labor in symptomatic patients.

Bolotskikh Vyacheslav, Borisova Vera

Клиническое исследованиеСтатьяПеревод в очереди

Аннотация

AIM: We aimed to evaluate the combined value of placental alpha microglobulin-1 (PAMG-1) and cervical length (CL) via transvaginal ultrasound for assessing risk of imminent spontaneous preterm delivery in patients presenting with threatened preterm labor (PTL).

METHODS

Clinical exam, PAMG-1 test, cardiotocography, and CL measurement via transvaginal ultrasound were performed on all patients meeting inclusion criteria. Ninety-nine patients at 22+0 -36+6 gestational weeks with the symptoms of PTL were included. The interval between sample collection and delivery was measured for each method.

RESULTS

Performance metrics were calculated for PAMG-1 test, CL < 25 mm, and contractions ≥ 8/h. The sensitivity, specificity, positive predictive value, and negative predictive value for the PAMG-1 test were 100%, 95%, 75%, 100% and 100%, 98%, 88%, 100% for 7 and 14 days, respectively; the respective values for CL < 25 mm were 83%, 59%, 22%, 96% and 79%, 59%, 24%, 94% for 7 and 14 days; and those for contractions ≥ 8/h were 42%, 38%, 8%, 83% and 43%, 38%, 10%, 80% for 7 and 14 days. Specificity for the PAMG-1 test was statistically significant (P < 0.001) in pairwise comparisons for all other methods. Patients were divided into four groups for analysis of PAMG-1 test performance as follows: CL < 15 mm (100%, 100%, 100%, 100% and 100%, 100%, 100%, 100% for 7 and 14 days, respectively); CL < 25 mm (100%, 94%, 83%, 100% and 100%, 97%, 92%, 100% for 7 and 14 days, respectively); CL of 15-30 mm (100%, 95%, 64%, 100% and 100%, 97%, 82%, 100% for 7 and 14 days, respectively); and CL ≥ 30 mm (100%, 100%, 100%, 100% and 100%, 100%, 100%, 100% for 7 and 14 days, respectively).

CONCLUSION

The use of the PAMG-1 test in patients with a CL of 15-30 mm is highly predictive of imminent spontaneous preterm delivery in women presenting with threatened PTL and could save hospital resources.

Для цитирования: Bolotskikh Vyacheslav, Borisova Vera. Combined value of placental alpha microglobulin-1 detection and cervical length via transvaginal ultrasound in the diagnosis of preterm labor in symptomatic patients.. The journal of obstetrics and gynaecology research. 2017. DOI: 10.1111/jog.13366.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.