MedElevator Войти в исследования
← Поиск публикаций
Медицинская библиотека · Chinese medical journal · 2012

Hand-assisted-drawing-needle running suture with a curved needle: an effective technique to create a W-ileal neobladder.

Fang Dan-Bo, Cai Song-Liang, Jin Xiao-Dong, Chen Jun, Jin Bai-Ye, Zheng Xiang-Yi, Wang Chao-Jun, Tan Fu-Qing, Wang Shuo, Shen Bo-Hua, Zhu Xuan-Wen, Xie Li-Ping

СтатьяПеревод в очереди

Аннотация

BACKGROUND

An important milestone in the area of urinary diversion was the advent of a series of orthotopic bladder substitution (OBS). However, reconstruction of OBS by the traditional hand suture method (THSM) is a time-consuming process. Stapling techniques are considered to be inferior to hand-sewn methods. We report our experience and functional results in patients with W-ileal neobladder by a hand-assisted-drawing-needle running suture (HADNRS).

METHODS

Between April 1993 and December 2011, 347 patients (338 men and 9 women) aged 28 - 77 years (median age: 59 years) underwent radical cystectomy, followed by the creation of a modified W-ileal neobladder by HADNRS with a curved needle. A total of 347 (20 patients in 2003) were evaluated by urodynamic tests.

RESULTS

The operative time ranged from 110 to 310 minutes (mean 148 minutes), and the mean time of reconstruction by HADNRS, excluding ureterointestinal and ileouretral anastomosis, was (20.2 ± 4.3) minutes. Histopathological analysis of removed specimens showed that 317 patients had transitional cell bladder carcinoma. Of these 317 patients, 19 also had squamous carcinoma and 13 had adenocarcinoma. Glandularis and prostate cancer occurred in 16 and 14 patients, respectively. Three patients (0.8%) had neobladder abdominal fistula. No other early complications or injury to the surgeon's hands occurred due to HADNRS. Of the 20 cases with urodynamic examinations in 2003, two suffered from daytime incontinence and six had nocturnal incontinence. The maximum capacity of the neobladder was (492.9 ± 177.8) ml, and the maximum pressure within the reservoir at the end of filling was (32.1 ± 8.6) cmH2O.

CONCLUSION

Reconstruction of W-ileal neobladder by HADNRS is effective and economical.

Для цитирования: Fang Dan-Bo, Cai Song-Liang, Jin Xiao-Dong, Chen Jun, Jin Bai-Ye, Zheng Xiang-Yi, Wang Chao-Jun, Tan Fu-Qing, Wang Shuo, Shen Bo-Hua, Zhu Xuan-Wen, Xie Li-Ping. Hand-assisted-drawing-needle running suture with a curved needle: an effective technique to create a W-ileal neobladder.. Chinese medical journal. 2012.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.