MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jcms.2020.06.003

Медицинская библиотека · Journal of cranio-maxillo-facial surgery : official publication of the European Association for Cranio-Maxillo-Facial Surgery · 2020

Evaluation of effectiveness of three-dimensional printed ear splint therapy following ear elevation surgery in microtia patients: A randomized controlled trial.

Xu Jia, Aung Zin Mar, Cheong Sousan, Won Taeho, Zhang Ruhong, Xu Feng, Fan Jiajun, Han Dong

СтатьяРандомизированное исследованиеПеревод в очереди

Аннотация

AIM: This study aimed to compare the effectiveness of a 3D-printed ear splint with that of a conventional thermoplastic ear splint after microtia reconstruction.

METHODS

Patients who underwent ear elevation surgery with postauricular fascia coverage between October 2017 and October 2018 were included. They were randomly divided into the experimental group (3D-printed ear splint) and the control group (thermoplastic ear splint) and underwent routine postoperative rehabilitation and antiscar therapy. Splint therapy was initiated 4 weeks postoperatively and continued until 24 weeks postoperatively. The evaluated indices were the Vancouver scar scale score (VSS score), cranioauricular distance, patient compliance, complications (dermatitis, skin ulcers, skin necrosis), and patient satisfaction. A two-group t-test was carried out to compare all variables except patient satisfaction, which was compared using the Mann-Whitney U-test; p < 0.05 was considered significant.

RESULTS

Twenty patients were included in each group. At 4 weeks postoperatively, the VSS score (p = 0.748) and cranioauricular distance (p = 0.647) showed no significant differences between the groups. At 24 weeks postoperatively, the mean VSS scores were 4.85 ± 1.46 and 6.25 ± 1.74 (p = 0.009), the mean cranioauricular distances were 15.80 ± 1.82 mm and 13.95 ± 1.93 mm (p = 0.004), and the patient satisfaction scores were 4.5 ± 0.51 and 3.7 ± 0.47 (p < 0.001) in the experimental group and the control group, respectively, all showing significant differences. Two patients in each group exhibited skin irritation or skin ulcers, which resolved after 6 months of follow-up.

CONCLUSION

The application of 3D-printed ear splints provides better inhibition of scar contracture, better maintenance of ear projection and higher patient satisfaction than conventional ear splints following ear elevation surgery in microtia patients. Therefore, 3D-printed ear splints should be preferred over conventional ear splints whenever possible.

Для цитирования: Xu Jia, Aung Zin Mar, Cheong Sousan, Won Taeho, Zhang Ruhong, Xu Feng, Fan Jiajun, Han Dong. Evaluation of effectiveness of three-dimensional printed ear splint therapy following ear elevation surgery in microtia patients: A randomized controlled trial.. Journal of cranio-maxillo-facial surgery : official publication of the European Association for Cranio-Maxillo-Facial Surgery. 2020. DOI: 10.1016/j.jcms.2020.06.003.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.