MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1186/s12872-026-05772-2

Медицинская библиотека · BMC cardiovascular disorders · 2026

Evaluation of non-dilated left ventricular cardiomyopathy patients with reduced and preserved left ventricular ejection fraction using cardiac magnetic resonance feature tracking technology.

Yan Chunlong, Li Shuang, Zhuang Baiyan, Yang Shujuan, Liu Jiayi, Xu Lei

СтатьяПеревод в очереди

Аннотация

BACKGROUND

To investigate the diagnostic value of cardiac magnetic resonance imaging feature tracking (CMR-FT) in evaluating patients with non-dilated left ventricular cardiomyopathy (NDLVC) and either reduced or preserved left ventricular ejection fraction (LVEF). MATERIALS AND

METHODS

This retrospective study enrolled 60 patients with NDLVC, including 30 with reduced LVEF (NDLVC-rLVEF, LVEF < 50%) and 30 with preserved LVEF (NDLVC-pLVEF, LVEF ≥ 50%), along with 30 healthy controls. Using the CVI42 post-processing software, conventional left ventricular functional parameters and 2D/3D global strain parameters were obtained, including global radial strain (GRS), global circumferential strain (GCS), and global longitudinal strain (GLS). Group differences in these parameters were analyzed. The diagnostic efficacy of strain parameters in NDLVC patients with reduced LVEF was evaluated using receiver operating characteristic (ROC) curve analysis.

RESULTS

(1) Compared to the NDLVC-pLVEF group, the NDLVC-rLVEF group was older (P < 0.05) and had a higher prevalence of hyperlipidemia and alcohol consumption history. (2) Compared to the control group, the NDLVC-pLVEF group showed a significant increase in LV mass at ED (P < 0.05). Compared to the NDLVC-pLVEF group, the NDLVC-rLVEF group exhibited significantly increased left ventricular end-systolic volume (LVESV) and LV mass at ED (P < 0.05), while left ventricular stroke volume (LVSV), left ventricular cardiac output (LVCO), left ventricular ejection fraction (LVEF), absolute values of GRS (2D/3D), GCS (2D/3D), GLS (2D/3D) were significantly reduced (P < 0.05). (3) ROC curve analysis revealed that the AUC values for GRS (2D), GCS (2D), GLS (2D), GRS (3D), GCS (3D), and GLS (3D) in distinguishing the NDLVC-rLVEF group from NDLVC-pLVEF group were 0.980, 0.974, 0.941, 0.908, 0.981, and 0.843, respectively.

CONCLUSION

CMR-FT technique demonstrates significant diagnostic value in differentiating NDLVC patients with both reduced and preserved LVEF. Both 2D and 3D strain parameters exhibit high diagnostic efficacy.

Для цитирования: Yan Chunlong, Li Shuang, Zhuang Baiyan, Yang Shujuan, Liu Jiayi, Xu Lei. Evaluation of non-dilated left ventricular cardiomyopathy patients with reduced and preserved left ventricular ejection fraction using cardiac magnetic resonance feature tracking technology.. BMC cardiovascular disorders. 2026. DOI: 10.1186/s12872-026-05772-2.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.