MedElevator Войти в исследования
← Поиск публикаций

DOI 10.31744/einstein_journal/2026ao1827

Медицинская библиотека · Einstein (Sao Paulo, Brazil) · 2026

Accuracy of oxidative stress markers for predicting delayed graft function lasting longer than a week in deceased-donor kidney transplantation.

Ribeiro Neto João Paulo, Batista Thales Paulo, Leão Cristiano Souza, Torres Leuridan Cavalcante, Dias Danielle da Silva, Angelis Kátia De

СтатьяПеревод в очереди

Аннотация

OBJECTIVE

To assess the accuracy of oxidative stress markers in predicting delayed graft function (DGF) lasting more than one week after deceased-donor kidney transplantation (KTx).

METHODS

A translational pilot study was carried out and a five-step hierarchical diagnostic accuracy strategy was applied to evaluate the predictive value of oxidative stress markers for DGF >7 days in adult patients with end-stage kidney disease undergoing deceased-donor KTx. Statistics comprise multiple conventional methods, C-statistics, and diagnostic test performance measures.

RESULTS

Cohort analysis of 27 consecutive patients revealed that 33.3% (9/27) developed DGF >7 days. Assessment of the oxidative stress markers selected in the first statistical step comparing donors and controls revealed a significant correlation of the DGF duration with the recipient's protein oxidation (ρ=0.466; p=0.022) as well as donor's hydrogen peroxide (ρ=-0.489; p<0.014). The areas under the curve were 0.683 (95% confidence interval [95%CI], 0.458-0.859; p=0.224) and 0.746 (95%CI=0.534-0.897; p=0.019), respectively. A cutoff of ≤14 μM H2O2 had the highest level of discriminating power for predicting DGF >7 days. The sensitivity, specificity, positive predictive value, negative predictive value, and overall diagnostic accuracy to identify patients at risk for experiencing DGF >7 days was 85.7%, 61.1%, 46.1%, 91.7%, and 68%, respectively.

CONCLUSION

Donor hydrogen peroxide was identified as a potential predictor of DGF >7 days in patients who underwent deceased-donor KTx. A cut-off value of ≤14 μmol/L is suggested to stratify patients at high risk of requiring dialysis beyond the first post-transplant week.

Для цитирования: Ribeiro Neto João Paulo, Batista Thales Paulo, Leão Cristiano Souza, Torres Leuridan Cavalcante, Dias Danielle da Silva, Angelis Kátia De. Accuracy of oxidative stress markers for predicting delayed graft function lasting longer than a week in deceased-donor kidney transplantation.. Einstein (Sao Paulo, Brazil). 2026. DOI: 10.31744/einstein_journal/2026ao1827.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.