m+Medelevator.RU
← Поиск публикаций
Zhongguo Zhong yao za zhi = Zhongguo zhongyao zazhi = China journal of Chinese materia medica · 2026

[Development of a quality control method for Polygalae Radix and exploration of its inter-column transfer strategy].

СтатьяОценочное исследованиеАннотация на английскомНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Xie Hu-Min, Cui Xiao-Qing, Chen Wan-Jin, Lu Chen-Na, Feng Wei-Hong, Liu Xiao-Qian, Sun Xiao-Li, Li Peng-Yue, Li Yan-Rong, Wang Zhi-Min, Li Chun

Аннотация

This study aimed to develop an ultra-performance liquid chromatography(UPLC) method for the quantitative analysis of xanthones and oligosaccharide esters in Polygalae Radix(PR), and to explore a retention-time-ratio-based strategy for inter-column method transfer. Chromatographic separation was performed on a Waters ACQUITY UPLC BEH C_(18) column(2.1 mm×50 mm, 1.7 μm) by gradient elution using 0.1% formic acid in water and acetonitrile with detection at 238 nm. The UPLC fingerprints of 31 batches of PR samples were established, with 21 common peaks marked and identified by UPLC-Q-TOF-MS~E. Through systematic methodological validation, a quantitative method was developed for the simultaneous determination of 7 bioactive components, namely sibiricose A_1, sibiricaxanthone B, polygalaxanthone Ⅷ, polygalaxanthone Ⅺ, polygalaxanthone Ⅲ, 3,6'-disinapoyl sucrose, and tenuifoliside A. A quantitative analysis of multiple components by single marker(QAMS) method was established using polygalaxanthone Ⅲ as the internal reference substance, and its accuracy was compared with that of the external standard method(ESM). The feasibility of method transfer across different columns and instruments was also investigated. All 7 analytes showed good linearity(r>0.999) within their respective concentration ranges with mean recoveries of 94.31%-99.02%(RSD<2.0%, n=6). The relative error(RE) between QAMS and ESM was less than 4.0%, and the paired t-test indicated no significant difference between the two methods. Preliminary studies of method transfer on 9 C_(18) columns from 3 manufacturers on Waters UPLC systems of two models demonstrated that gradient time adjustment based on retention time ratio could maintain the elution behavior and separation characteristics of the target peaks, though the generalizability of this strategy requires further validation. The established UPLC-QAMS method is accurate and reliable for the quality control of PR. The inter-column method transfer strategy provides preliminary reference for the broader application of analytical methods.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты