Artificial intelligence-based model for the interpretation and reporting of standard automated perimetry.

David Joacy Pedro Franco, Rosa Alexandre Antonio Marques, Scherer Rafael, Teixeira Cláudio Eduardo Corrêa, Costa Douglas

СтатьяНаблюдательное исследованиеПеревод в очереди

Аннотация

PURPOSE: Standard automated perimetry has been the standard method for measuring visual field changes for several years. It can measure an individual's ability to detect a light stimulus from a uniformly illuminated background. In the management of glaucoma, the primary objective of perimetry is the identification and quantification of visual field abnormalities. It also serves as a longitudinal evaluation for the detection of disease progression. The development of artificial intelligence--based models capable of interpreting tests could combine technological development with improved access to healthcare.

METHODS

In this observational, cross-sectional, descriptive study, we used an artificial intelligence-based model [Inception V3] to interpret gray-scale crops from standard automated perimetry that were performed in an ophthalmology clinic in the Brazilian Amazon rainforest between January 2018 and December 2022.

RESULTS

The study included 1,519 standard automated perimetry test results that were performed using Humphrey HFA-II-i-750 (Zeiss Meditech). The Subsequently, 70%, 10%, and 20% of the dataset were used for training, validation, and testing, respectively. The model achieved 80% (68.23%-88.9%) sensitivity and 94.64% (88.8%-98%) specificity for detecting altered perimetry results. Furthermore, the area under the receiver operating characteristic curve was 0.93.

CONCLUSIONS

The integration of artificial intelligence in the diagnosis, screening, and monitoring of pathologies represents a paradigm shift in ophthalmology, enabling significant improvements in safety, efficiency, availability, and accessibility of treatment.

Для цитирования: David Joacy Pedro Franco, Rosa Alexandre Antonio Marques, Scherer Rafael, Teixeira Cláudio Eduardo Corrêa, Costa Douglas. Artificial intelligence-based model for the interpretation and reporting of standard automated perimetry.. Arquivos brasileiros de oftalmologia. 2025. DOI: 10.5935/0004-2749.2024-0270.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.