MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1161/circheartfailure.123.010904

Медицинская библиотека · Circulation. Heart failure · 2024

Early Outcomes in Patients With LVAD Undergoing Heart Transplant via Use of the SherpaPak Cardiac Transport System.

Lerman Joseph B, Patel Chetan B, Casalinova Sarah, Nicoara Alina, Holley Christopher L, Leacche Marzia, Silvestry Scott, Zuckermann Andreas, D'Alessandro David A, Milano Carmelo A, Schroder Jacob N, DeVore Adam D

СтатьяМногоцентровое исследованиеПеревод в очереди

Аннотация

BACKGROUND

Heart transplant (HT) in recipients with left ventricular assist devices (LVADs) is associated with poor early post-HT outcomes, including primary graft dysfunction (PGD). As complicated heart explants in recipients with LVADs may produce longer ischemic times, innovations in donor heart preservation may yield improved post-HT outcomes. The SherpaPak Cardiac Transport System is an organ preservation technology that maintains donor heart temperatures between 4 °C and 8 °C, which may minimize ischemic and cold-induced graft injuries. This analysis sought to identify whether the use of SherpaPak versus traditional cold storage was associated with differential outcomes among patients with durable LVAD undergoing HT.

METHODS

Global Utilization and Registry Database for Improved Heart Preservation-Heart (NCT04141605) is a multicenter registry assessing post-HT outcomes comparing 2 methods of donor heart preservation: SherpaPak versus traditional cold storage. A retrospective review of all patients with durable LVAD who underwent HT was performed. Outcomes assessed included rates of PGD, post-HT mechanical circulatory support use, and 30-day and 1-year survival.

RESULTS

SherpaPak (n=149) and traditional cold storage (n=178) patients had similar baseline characteristics. SherpaPak use was associated with reduced PGD (adjusted odds ratio, 0.56 [95% CI, 0.32-0.99]; P=0.045) and severe PGD (adjusted odds ratio, 0.31 [95% CI, 0.13-0.75]; P=0.009), despite an increased total ischemic time in the SherpaPak group. Propensity matched analysis also noted a trend toward reduced intensive care unit (SherpaPak 7.5±6.4 days versus traditional cold storage 11.3±18.8 days; P=0.09) and hospital (SherpaPak 20.5±11.9 days versus traditional cold storage 28.7±37.0 days; P=0.06) lengths of stay. The 30-day and 1-year survival was similar between groups.

CONCLUSIONS

SherpaPak use was associated with improved early post-HT outcomes among patients with LVAD undergoing HT. This innovation in preservation technology may be an option for HT candidates at increased risk for PGD.

REGISTRATION: URL: https://www.clinicaltrials.gov; Unique identifier: NCT04141605.

Для цитирования: Lerman Joseph B, Patel Chetan B, Casalinova Sarah, Nicoara Alina, Holley Christopher L, Leacche Marzia, Silvestry Scott, Zuckermann Andreas, D'Alessandro David A, Milano Carmelo A, Schroder Jacob N, DeVore Adam D. Early Outcomes in Patients With LVAD Undergoing Heart Transplant via Use of the SherpaPak Cardiac Transport System.. Circulation. Heart failure. 2024. DOI: 10.1161/circheartfailure.123.010904.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.