MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1259/bjr.20220495

Медицинская библиотека · The British journal of radiology · 2023

Ultra-low-dose CT is feasible for torsion measurement of the lower limb in patients with metal implants.

Keller Gabriel, Grünwald Leonard, Springer Fabian

СтатьяПеревод в очереди

Аннотация

OBJECTIVES

Patients who need torsion measurement of the lower limb often have metal implants hindering e.g. MRI. A new ultra-low-dose (ULD-)CT protocol might be feasible for torsion measurement at cost of relatively low radiation exposure.

METHODS

We retrospectively included all patients with clinically indicated torsion measurement in the period July 2019 to June 2021 and metal implants in the scanning field. The ULD-CT protocol comprised automated tube current time product and automated tube voltage with reference settings of 100kV/20mAs (hip), 80kV/20mAs (knee) and 80kV/10mAs (ankle). Femoral neck anteversion, tibial, intra-articular knee and overall leg torsion measurements were performed by two radiologists independently. Diagnostic confidence regarding the delineation of the relevant cortical bone was rated on a 5-point Likert scale (1 = non-diagnostic, 5 = excellent).

RESULTS

102 consecutive patients could be included (BMI 27.38 ± 5.85) with 154 metal implants. Median total dose length product of the ULD-CT-torsion measurement was 16.5mGycm [11-39]. Both readers showed high agreement with a maximum torsional difference of 4.1°. Diagnostic confidence was rated best (5/5) in 92.2% (reader 1) and 93.1% (reader 2) with a worst rating of 3/5.

CONCLUSION

The new ULD-CT protocol is feasible for torsion measurement of the lower limb - even in patients with metal implants.

ADVANCES IN KNOWLEDGE: Metal implants are not an obstacle for ULD-CT torsion measurements of the lower limb.

Для цитирования: Keller Gabriel, Grünwald Leonard, Springer Fabian. Ultra-low-dose CT is feasible for torsion measurement of the lower limb in patients with metal implants.. The British journal of radiology. 2023. DOI: 10.1259/bjr.20220495.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.