MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1038/jp.2014.164

Медицинская библиотека · Journal of perinatology : official journal of the California Perinatal Association · 2014

Early radiologic evidence of severe respiratory distress syndrome as a predictor of nasal continuous positive airway pressure failure in extremely low birth weight newborns.

Tagliaferro T, Bateman D, Ruzal-Shapiro C, Polin R A

СтатьяПеревод в очереди

Аннотация

OBJECTIVE

To determine whether early radiologic evidence of severe respiratory distress syndrome (RDS) is predictive of nasal continuous positive airway pressure (CPAP) failure in extremely low birth weight (ELBW) infants during the first 72 h of age.

STUDY

DESIGN

Retrospective analysis of 235 consecutively inborn ELBW infants who received initial support with CPAP. CPAP success (n=151) and CPAP failure (n=84) groups were designated according to outcome within the first 72 h of age. We assessed the ability of radiologic evidence of severe RDS in the initial chest radiograph, alone and in combination with other variables available in the first hours of life, to predict CPAP failure.

RESULT: Severe RDS had a positive predictive value (PPV) of 0.81 (95% confidence interval (CI) 0.64, 0.92) for CPAP failure. The combination of severe RDS and gestational age (GA) ⩽ 26 weeks had a PPV of 0.92 (95% CI 0.68, 0.96).

CONCLUSION

Early radiologic evidence of severe RDS is predictive of CPAP failure, especially in infants with GA ⩽ 26 weeks.

Для цитирования: Tagliaferro T, Bateman D, Ruzal-Shapiro C, Polin R A. Early radiologic evidence of severe respiratory distress syndrome as a predictor of nasal continuous positive airway pressure failure in extremely low birth weight newborns.. Journal of perinatology : official journal of the California Perinatal Association. 2014. DOI: 10.1038/jp.2014.164.