MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1093/sexmed/qfag058

Медицинская библиотека · Sexual medicine · 2026

Efficacy, reliability, and patient satisfaction with Rigicon Infla10 X and Infla10 AX inflatable penile prostheses: a retrospective single-center analysis.

Cetin Bugra, Wilson Steven K, Atwater Britney L, Gross Martin S, Kirkik Duygu, Yazici Gokhan, Onuk Ozkan

СтатьяПеревод в очереди

Аннотация

INTRODUCTION

Inflatable penile prosthesis implantation is a well-established treatment option for men with erectile dysfunction refractory to conservative therapies. However, patient-reported outcome data for the Rigicon Infla10 prosthesis remain limited. This study aimed to evaluate 12-month patient-reported outcomes following primary implantation of Rigicon Infla10 X and Infla10 AX devices and to explore potential differences according to implant model and pump type.

METHODS

This retrospective single-center, single-surgeon cohort study included 275 patients who underwent primary Rigicon Infla10 X or Infla10 AX implantation between 2021 and 2024 and completed 12-month follow-up. Erectile function was assessed using the International Index of Erectile Function-Erectile Function domain (IIEF-EF), while postoperative satisfaction was evaluated using the Quality of Life and Sexuality with Penile Prosthesis (QoLSPP) questionnaire. Ease of inflation and deflation was assessed using a 10-point numeric rating scale. Subgroup analyses were performed according to implant model and pump type.

RESULTS

Mean preoperative IIEF-EF score increased from 6.09 ± 1.47 to 24.07 ± 1.78 at 12 months. The overall mean QoLSPP total score was 4.19 ± 0.16. QoLSPP scores did not differ significantly between the Infla10 X and Infla10 AX groups (4.20 ± 0.18 vs. 4.18 ± 0.16; P = .436). Patients using the Pulse pump reported significantly higher ease-of-inflation and ease-of-deflation scores compared with those using the earlier-generation pump (both P < .001), whereas QoLSPP total scores were similar between pump groups (P = .821). The overall complication rate was 5.5%, and device infection occurred in one patient (0.4%).

DISCUSSION: Primary Rigicon Infla10 implantation was associated with substantial improvement in erectile function and favorable patient-reported outcomes at 12 months. Although the Pulse pump was associated with improved ease-of-use ratings, these differences did not translate into higher overall satisfaction scores. Interpretation of pump-related comparisons should be cautious because pump type was era-dependent and not randomly assigned. Prospective studies with longer follow-up are warranted to confirm these findings and further evaluate device-related outcomes.

Для цитирования: Cetin Bugra, Wilson Steven K, Atwater Britney L, Gross Martin S, Kirkik Duygu, Yazici Gokhan, Onuk Ozkan. Efficacy, reliability, and patient satisfaction with Rigicon Infla10 X and Infla10 AX inflatable penile prostheses: a retrospective single-center analysis.. Sexual medicine. 2026. DOI: 10.1093/sexmed/qfag058.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.