MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1155/2022/3390338

Медицинская библиотека · BioMed research international · 2022

A Novel Acoustic Uroflowmetry-Based Mobile App Voiding Diary: Comparison with Conventional Paper-Based Voiding Diary.

Kim Jung Kwon, Kim Hwanik, Ho Jin-Nyoung, Jeong Seong Jin, Lee Sangchul

СтатьяПеревод в очереди

Аннотация

OBJECTIVES

To evaluate the usefulness of a novel acoustic uroflowmetry- (UFM-) based mobile application (app) voiding diary (VD) focusing on the (1) compliance and (2) correlation with a conventional paper-based VD.

MATERIALS AND

METHODS

A total of 78 patients were included between December 2019 and June 2020, and a subsequent review of all data was performed. The analyzed data were as follows: (1) survey of convenience/satisfaction/preference comparing the two methods, (2) compliance regarding the completeness of both methods, and (3) correlation of each metric (24-hour urine volume, nocturnal urine volume, nocturnal polyuria index, total number of voids, number of daytime voids, number of nocturnal voids, and maximal bladder capacity) between the two methods.

RESULTS

The survey results of convenience, satisfaction, and preference were as follows. With regard to convenience and satisfaction area, higher scores are reported in the mobile app VD (mean ± standard deviation (SD); convenience: 7.47 ± 2.19 [app] vs. 4.20 ± 2.49 [paper]; satisfaction: 7.36 ± 2.17 [app] vs. 5.07 ± 2.65 [paper]). The median score of the overall preference for using the mobile app instead of the paper-based VD was 9 out of 10 (mean ± SD7.82 ± 2.68). We also found a good correlation between the two methods for nocturnal urine volume (r = 0.55, p = 0.04), nocturnal polyuria index (r = 0.66, p = 0.23), total number of voids (r = 0.9, p = 0.02), number of nocturnal voids (r = 0.83, p = 0.02), and maximal bladder capacity (r = 0.89, p = 0.04).

CONCLUSION

The acoustic UFM-based mobile app VD demonstrated favorable findings compared to the conventional paper-based VD.

Для цитирования: Kim Jung Kwon, Kim Hwanik, Ho Jin-Nyoung, Jeong Seong Jin, Lee Sangchul. A Novel Acoustic Uroflowmetry-Based Mobile App Voiding Diary: Comparison with Conventional Paper-Based Voiding Diary.. BioMed research international. 2022. DOI: 10.1155/2022/3390338.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.