m+Medelevator.RU
← Поиск публикаций
The Annals of thoracic surgery · 2002

Cardiac troponin I in neonates undergoing the arterial switch operation.

СтатьяПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Imura Hajime, Modi Paul, Pawade Ashwinikumar, Parry Andrew J, Suleiman M Saadeh, Angelini Gianni D, Caputo Massimo

Аннотация

BACKGROUND: Cardiac troponin I (TnI) is a sensitive and specific marker of myocardial injury, but little is known about its release after complex congenital heart surgery. We investigated whether TnI correlates with early clinical outcome in neonates undergoing the arterial switch operation (ASO) for transposition of the great arteries (TGA).

METHODS: Troponin I was measured serially up to 48 hours postoperatively in 31 neonates undergoing the ASO alone (simple TGA) and 9 neonates undergoing the ASO combined with other procedures (complex TGA) (eg, closure of a ventricular septal defect) and correlated with intraoperative and postoperative clinical parameters.

RESULTS: There was no mortality. Troponin I peaked at either 4 or 12 hours postoperatively in all patients (median for simple TGA = 3.4 ng/mL, interquartile range 2.4 to 4.6; median for complex TGA = 4.7 ng/mL, interquartile range 3.2 to 6.8, p = 0.20). Peak TnI correlated with the durations of inotropic support (r = 0.54, p < 0.001), ventilation (r = 0.51, p < 0.01), and intensive care unit stay (r = 0.50, p < 0.01). The duration of cardiopulmonary bypass, aortic cross-clamping, and circulatory arrest did not correlate with the peak or total TnI release. The duration of aortic cross-clamping correlated poorly with the duration of inotropic support (r = 0.40, p < 0.05). The complex TGA group had longer aortic cross-clamp times, required more postoperative inotropic support, and had significantly higher total TnI release compared with the simple TGA group.

CONCLUSIONS: There are weak but statistically significant correlations between peak TnI and clinical outcome. Complexity of the defect and ischemic times may be as useful to predict outcome in this group of patients.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты