m+Medelevator.RU
← Поиск публикаций
Laboratory investigation; a journal of technical methods and pathology · 2026

Optimal Formalin-Fixed Paraffin-Embedded Sample Preservation for Efficient Staining in Multiplex Imaging.

СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Delarue Yuna, Marec Nadège, Le Rochais Marion, Le Dantec Christelle, Garaud Soizic, Uguen Arnaud, Cornec Divi, Jamin Christophe, Pochard Pierre, Hemon Patrice

Аннотация

The accuracy of immunohistochemical techniques depends critically on the preservation of antigenic integrity in tissue samples. Although formalin-fixed paraffin-embedded tissues are commonly used for long-term storage, several studies reported signal degradation over time. However, the extent of this degradation and the influence of storage conditions on a wide range of markers remain poorly characterized. In this study, tissue blocks collected over an 8-year period and tissue sections stored under different conditions (room temperature [RT], 4 °C, -20 °C, and -80 °C) were analyzed. Twenty-five antibodies targeting immune, stromal, and structural markers were used to stain 4 different tissue sections. Samples were acquired using imaging mass cytometry. Signal intensities were first quantified, then the data were analyzed, before and after normalization, using the imcRtools pipeline. A gradual loss of signal intensity was observed in blocks stored at RT for more than 6 years, affecting the detection of certain markers regardless of tissue type. For some sections, significant signal degradation was observed after only 1 week at RT and for others after 1 month of storage. Markers such as CD20, CD45, and CD45RA proved to be particularly sensitive. Storage at -20 °C or -80 °C preserved the quality of the staining, whereas storage at 4 °C only allowed partial preservation. Normalization corrected some variations but did not enable the recovery of signals that were severely altered or absent. Commonly used RT storage causes a gradual reduction in imaging mass cytometry--detected immunoreactivity, which may affect scientific interpretation and diagnosis. Storing sections at -20 °C is, therefore, an effective and accessible solution. For retrospective studies, we recommend using blocks that are less than 6 years old. Overall, these results highlight the importance of preestablished standardized preservation protocols to ensure the reproducibility of analyses.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты