MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1021/acs.analchem.3c05141

Медицинская библиотека · Analytical chemistry · 2024

Inner-Wall Coated Nanopipette Microextraction for Quantitative Analysis of Per- and Polyfluoroalkyl Substances in Single Cells Using Mass Spectrometry.

Deng Jiewei, Xie Jialiang, Wang Chao, Wu YueHua, Luan Tiangang, Yang Yunyun

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

Per- and polyfluoroalkyl substances (PFASs) are a series of organic pollutants with potential cytotoxicity and biotoxicity. Accurate and sensitive detection of trace PFASs in single cells can provide insights into investigating their cytotoxicity, carcinogenicity, and mutagenicity. Here we report the development of an inner-wall coated nanopipette microextraction coupled with induced nanoelectrospray ionization mass spectrometry (InESI-MS) method and its application for rapid, sensitive, and accurate analysis of trace PFASs in single cells. A specially designed inner-wall coated nanopipette was prepared for sampling of the cytoplasm from a single cell, and the trace PFASs in the cytoplasm were selectively enriched into the coating via reversed-phase adsorption, ion bonding adsorption, and π-π interaction mechanisms. After the extraction, the cytoplasm was removed, and the enriched PFASs were then desorbed into some organic solvent, applying an alternating current (AC) voltage to the inner-wall coated nanopipette for InESI-MS analysis. The inner-wall coated nanopipette showed an exhaustive extraction to the trace PFASs in one single cell, and thus, the mass of each target analyte in the cytoplasm can be calculated via an internal standard calibration curve method, avoiding the measurement of ultrasmall volume cytoplasm for one single cell. By using the inner-wall coated nanopipette microextraction coupled with InESI-MS method, trace PFASs accumulated in the LO2 cells with pollutant exposure were successfully detected, and the accumulative behaviors and heterogeneities of PFASs in single cells were explored.

Для цитирования: Deng Jiewei, Xie Jialiang, Wang Chao, Wu YueHua, Luan Tiangang, Yang Yunyun. Inner-Wall Coated Nanopipette Microextraction for Quantitative Analysis of Per- and Polyfluoroalkyl Substances in Single Cells Using Mass Spectrometry.. Analytical chemistry. 2024. DOI: 10.1021/acs.analchem.3c05141.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.