Journal of magnetic resonance imaging : JMRI · 2022

Zero Echo Time vs. T1-Weighted MRI for Assessment of Cortical and Medullary Bone Morphology Abnormalities Using CT as the Reference Standard.

СтатьяПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Xu Jun, Hu Yawen, Zhou Ruizhi, Sun Shiqing, Chen Haisong

Аннотация

BACKGROUND: Conventional MR pulse sequences result in poor signal from low T2 cortical bone because the minimum achievable echo time is limited. A sequence resulting in improved bone contrast is desirable.

PURPOSE: To evaluate the image quality and diagnostic performance of grayscale inversion zero echo time imaging (GI-ZTE) and grayscale inversion T1-weighted imaging (GI-T1WI) compared with computed tomography (CT).

STUDY TYPE: Prospective.

SUBJECTS: A total of 50 patients with musculoskeletal tumors or tumor-like diseases of the lower extremities having MRI and CT studies.

FIELD STRENGTH/SEQUENCE: GI-T1WI and GI-ZTE sequences at 1.5 T.

ASSESSMENT: Assessed cortical and medullary bone morphology abnormalities using CT as the reference standard. Three radiologists scored the images quality and recorded nine metrics to assess the diagnostic performance.

STATISTICAL TESTS: Differences in image quality were calculated using the Wilcoxon signed-rank test. The intraclass correlation coefficient (ICC) was used to analyze the agreement of quantitative lesion parameters between CT and MR sequences, as well as the interobserver reliability. A P value <0.05 was considered statistically significant.

RESULTS: Image quality score was significantly higher for CT images than GI-TIWI images. Except for radiologist 3 [4(0) vs 4 (1)], there was no significant difference in scores between CT and GI-ZTE [radiologist 1: 4 (0) vs 4 (0), P = 0.133; radiologist 2: 4 (0) vs 4 (0), P = 0.085]. There was good-excellent agreement between both MR sequences and CT for size, lesion number, location, sclerotic rim, expanded shell, destruction pattern, and matrix mineralization for all radiologists (ICC: 0.636-1.000). The consistency of periosteal reaction and penetration of the cortex was fair to good (0.481-0.729) between GI-T1WI and CT and good to excellent between GI-ZTE and CT (0.682-0.852).

DATA CONCLUSIONS: GI-ZTE images had superior intermodality agreement with CT images and allowed visualization of more cortical bone detail than GI-T1WI images.

EVIDENCE LEVEL: 1.

TECHNICAL EFFICACY: Stage 2.