DOI 10.1016/j.jvoice.2025.02.024
Vocal Function Changes in Patients With Benign Thyroid Nodules After Radiofrequency Ablation.
Аннотация
OBJECTIVE
To objectively evaluate changes in vocal function in patients with benign thyroid nodules following radiofrequency ablation (RFA).
METHODS
Seventy-five patients diagnosed with benign thyroid nodules who underwent RFA were included in the study. These patients received thyroid sonography both preRFA and 3 months postRFA. Additionally, vocal function assessments, including aerodynamic and acoustic evaluations, were performed at specific time points: preRFA, immediately postRFA, and 3 months postRFA.
RESULTS
The results indicated a significant decrease in maximum phonation time (MPT) immediately postRFA (MPT = 11.25; P < 0.001) and 3 months postRFA (MPT = 12.40; P = 0.007) compared with preRFA (MPT = 13.88), suggesting potential dysphonia. Additionally, compared with preRFA (jitter = 0.86; shimmer = 0.35), transient increases in jitter (jitter = 1.19; P = 0.013) and shimmer (shimmer = 0.37; P = 0.039) were observed immediately postRFA, returning to baseline at 3 months, indicating vocal recovery of the vibratory characteristics. No significant correlations were found between preRFA nodule volume (correlation coefficient = 0.002; P = 0.991) or volume reduction ratio (VRR; correlation coefficient = -0.129; P = 0.415) and MPT changes.
CONCLUSIONS
In patients with benign thyroid nodules, RFA affects both acoustic and aerodynamic vocal function. Regardless of initial nodule volume or high VRR at 3 months postablation, a significant decrease in MPT was observed. This study underscores the importance of objective vocal assessment for monitoring and guiding interventions for vocal recovery postRFA.
DATA AVAILABILITY: The datasets generated during and/or analyzed during the current study are available from the corresponding author on reasonable request.