MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/ajo.13162

Медицинская библиотека · The Australian & New Zealand journal of obstetrics & gynaecology · 2020

Accuracy of sonographic estimation of weight in fetuses with abdominal wall defects.

Spaulding Portia, Edwards Andrew, Coombs Peter, Davies-Tuck Miranda, Robinson Alice

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Accurate estimation of fetal weight is essential in guiding management of fetuses with abdominal wall defects (AWDs), as growth restriction is an important predictor of perinatal morbidity and mortality. Several sonographic formulae are available involving multiple biometric parameters, but abdominal circumference measurements may underestimate weight in fetuses with AWDs. No formula has yet shown superior accuracy.

AIMS: The objectives of this study were to evaluate, in fetuses with gastroschisis and omphalocoele, the accuracy of a sonographic estimated fetal weight (EFW) formula proposed by Siemer and colleagues, specifically for use in fetuses with AWDs compared to the commonly used Hadlock IV formula in estimating fetal weight, and detecting small for gestational age (SGA) fetuses.

MATERIALS AND

METHODS

A retrospective cohort of 113 fetuses with AWDs was identified from an Australian teaching hospital over 13 years. Pregnancy data and sonographic fetal biometry parameters were obtained. The accuracy of each formula in predicting birthweight was compared using Bland-Altman limits of agreement, and the intraclass correlation coefficient between EFW and actual birthweight. Performance of each formula in detecting SGA fetuses was determined.

RESULTS

The Siemer and Hadlock formulae have similar accuracies for predicting birthweight in fetuses with AWDs. The Hadlock formula has a higher detection rate for SGA < 10th centile and < 3rd centile compared to the Seimer formula (84% vs 68% and 83% vs 67% respectively), albeit with a higher false-positive rate.

CONCLUSION

There is no clear clinical advantage in using the Siemer formula, which is specifically designed for fetuses with AWDs, over the Hadlock formula to estimate weight in fetuses with AWDs.

Для цитирования: Spaulding Portia, Edwards Andrew, Coombs Peter, Davies-Tuck Miranda, Robinson Alice. Accuracy of sonographic estimation of weight in fetuses with abdominal wall defects.. The Australian & New Zealand journal of obstetrics & gynaecology. 2020. DOI: 10.1111/ajo.13162.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.