MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.ejvs.2019.06.028

Медицинская библиотека · European journal of vascular and endovascular surgery : the official journal of the European Society for Vascular Surgery · 2019

Haemodynamics of Different Configurations of a Left Subclavian Artery Stent Graft for Thoracic Endovascular Aortic Repair.

Tricarico Rosamaria, Tran-Son-Tay Roger, Laquian Liza, Scali Salvatore T, Lee Teng-Chun, Beck Adam W, Berceli Scott A, He Yong

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

OBJECTIVE

Branched stent grafts represent a viable option for left subclavian artery (LSA) revascularisation in patients treated by thoracic endovascular aortic repair (TEVAR) for Zone 2 lesions. This study investigated the haemodynamic performance of different LSA branched stent graft configurations as potential determinants of thrombotic and stroke risks.

METHODS

A three dimensional aortic arch geometry extracted from post-operative computed tomography images of a TEVAR patient using a single LSA branched aortic endograft was modified in silico to obtain ten potential LSA branched stent graft configurations: five down facing (0-5 - 10 mm aortic protrusion with 10-12 mm internal diameter), four curved (30-60° with antegrade/retrograde orientation), and one LSA orifice misalignment. The 0 mm down facing stent graft was considered base configuration. Computational fluid dynamic analyses were performed to identify differences in pressure, energy, and wall shear stress (WSS) based parameters.

RESULTS

Total pressure drop and energy loss variations among configurations were not greater than 5 mmHg (6% of mean arterial pressure) and 5.7 mW (0.7% of cardiac power), respectively. Protrusions up to 5 mm created clinically insignificant flow disturbances. However, stent graft protrusions further into the aortic lumen created more complex haemodynamics, characterised by larger energy loss and more prominent flow recirculation. Protrusion greater than 5 mm into the lumen was associated with larger areas of elevated maximum WSS (>20 Pa) along the outer surface of the branched stent graft.

CONCLUSION

Arterial haemodynamic characteristics are affected by LSA branched stent graft configurations, with pressure drops and energy losses likely to be clinically insignificant. The length of the stent graft protrusion into the aortic lumen generated the largest haemodynamic variations in the aortic system. Protrusions up to 5 mm have smaller risk of potential thrombus generation. Conversely, larger protrusions into the aortic lumen showed more disturbed haemodynamics, suggesting a greater risk of potential thrombus formation, which may be clinically important over time.

Для цитирования: Tricarico Rosamaria, Tran-Son-Tay Roger, Laquian Liza, Scali Salvatore T, Lee Teng-Chun, Beck Adam W, Berceli Scott A, He Yong. Haemodynamics of Different Configurations of a Left Subclavian Artery Stent Graft for Thoracic Endovascular Aortic Repair.. European journal of vascular and endovascular surgery : the official journal of the European Society for Vascular Surgery. 2019. DOI: 10.1016/j.ejvs.2019.06.028.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.