MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1053/j.semtcvs.2021.06.020

Медицинская библиотека · Seminars in thoracic and cardiovascular surgery · 2021

Mortality and Reoperation Risk After Bioprosthetic Aortic Valve Replacement in Young Adults With Congenital Heart Disease.

Fuller Stephanie M, Borisuk Michele J, Sleeper Lynn A, Bacha Emile, Burchill Luke, Guleserian Kristine, Ilbawi Michel, Razzouk Anees, Shinkawa Takeshi, Lu Minmin, Baird Christopher W

СтатьяПеревод в очереди

Аннотация

Bioprosthetic aortic valve replacement (bAVR) in patients with congenital heart disease is challenging due to age, size and complexity. Our objective was to assess survival and identify predictors of re-operation. Data were retrospectively collected for 314 patients undergoing bAVR at 8 centers from 2000-2014. Kaplan-Meier estimation of time to re-operation and Cox regression were utilized. Average age was 45.2 years (IQR 17.8-71.1) and 30% were <21. Indications were stenosis (48%), regurgitation (28%) and mixed (18%). Twenty-eight (9%) underwent prior AVR. Median valve size was 23mm (IQR 21, 25). Implanted valves included CE (Carpentier-Edwards) Perimount (47%), CE Magna/Magna Ease (29%), Sorin Mitroflow (9%), St Jude (2%) and other (13%). Median follow-up was 2.9 (IQR 1.2, 5.7) years. Overall, 11% required re-operation, 35% of whom had a Mitroflow and 65% were <21 years old. Time to re-operation varied among valve type (p=0.020). Crude 3-year rate was 20% in patients ≤21. Smaller valve size indexed to BSA was associated with re-operation (21.7 vs. 23.5 mm/m2). Predictors of reintervention by multivariable analysis were younger age (29% increase in hazard per 5-year decrease, p<0.001), Mitroflow (HR=4 to 8 versus other valves), and smaller valve size (20% increase in hazard per 1 mm decrease, p=0.002). The overall 1, 3 and 5-year survival rates were 94%, 90% and 85% without differences by valve (p=0.19). A concerning reduction in 5-year survival after bAVR is shown. Re-operation is common and varies by age and valve type. Further research is needed to guide valve choice and improve survival.

Для цитирования: Fuller Stephanie M, Borisuk Michele J, Sleeper Lynn A, Bacha Emile, Burchill Luke, Guleserian Kristine, Ilbawi Michel, Razzouk Anees, Shinkawa Takeshi, Lu Minmin, Baird Christopher W. Mortality and Reoperation Risk After Bioprosthetic Aortic Valve Replacement in Young Adults With Congenital Heart Disease.. Seminars in thoracic and cardiovascular surgery. 2021. DOI: 10.1053/j.semtcvs.2021.06.020.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.