MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.echo.2013.02.012

Медицинская библиотека · Journal of the American Society of Echocardiography : official publication of the American Society of Echocardiography · 2013

Doppler flow patterns in the right ventricle-to-pulmonary artery shunt and neo-aorta in infants with single right ventricle anomalies: impact on outcome after initial staged palliations.

Frommelt Peter C, Gerstenberger Eric, Baffa Jeanne, Border William L, Bradley Tim J, Colan Steven, Gorentz Jessica, Heydarian Haleh, John J Blaine, Lai Wyman W, Levine Jami, Lu Jimmy C, McCandless Rachel T, Miller Stephen, Nutting Arni, Ohye Richard G, Pearson Gail D, Wong Pierre C, Cohen Meryl S, Pediatric Heart Network Investigators

Сравнительное исследованиеСтатьяПоддержка NIH: внешняя программаПеревод в очереди

Аннотация

BACKGROUND

A Pediatric Heart Network trial compared outcomes in infants with single right ventricle anomalies undergoing Norwood procedures randomized to modified Blalock-Taussig shunt (MBTS) or right ventricle-to-pulmonary artery shunt (RVPAS). Doppler patterns in the neo-aorta and RVPAS may characterize physiologic changes after staged palliations that affect outcomes and right ventricular (RV) function.

METHODS

Neo-aortic cardiac index (CI), retrograde fraction (RF) in the descending aorta and RVPAS conduit, RVPAS/neo-aortic systolic ejection time ratio, and systolic/diastolic (S/D) ratio were measured early after Norwood, before stage II palliation, and at 14 months. These parameters were compared with transplantation-free survival, length of hospital stay, and RV functional indices.

RESULTS

In 529 subjects (mean follow-up period, 3.0 ± 2.1 years), neo-aortic CI and descending aortic RF were significantly higher in the MBTS cohort after Norwood. The RVPAS RF averaged <25% at both interstage intervals. Higher pre-stage II descending aortic RF was correlated with lower RV ejection fraction (R = -0.24; P = .032) at 14 months for the MBTS cohort. Higher post-Norwood CI (5.6 vs 4.4 L/min/m(2), P = .04) and lower S/D ratio (1.40 vs 1.68, P = .01) were correlated with better interstage transplantation-free survival for the RVPAS cohort. No other Doppler flow patterns were correlated with outcomes.

CONCLUSIONS

After the Norwood procedure, infants tolerated significant descending aortic RF (MBTS) and conduit RF (RVPAS), with little correlation with clinical outcomes or RV function. Neo-aortic CI, ejection time, and S/D ratios also had limited correlations with outcomes or RV function, but higher post-Norwood neo-aortic CI and lower S/D ratio were correlated with better interstage survival in those with RVPAS.

Для цитирования: Frommelt Peter C, Gerstenberger Eric, Baffa Jeanne, Border William L, Bradley Tim J, Colan Steven, Gorentz Jessica, Heydarian Haleh, John J Blaine, Lai Wyman W, Levine Jami, Lu Jimmy C, McCandless Rachel T, Miller Stephen, Nutting Arni, Ohye Richard G, Pearson Gail D, Wong Pierre C, Cohen Meryl S, Pediatric Heart Network Investigators. Doppler flow patterns in the right ventricle-to-pulmonary artery shunt and neo-aorta in infants with single right ventricle anomalies: impact on outcome after initial staged palliations.. Journal of the American Society of Echocardiography : official publication of the American Society of Echocardiography. 2013. DOI: 10.1016/j.echo.2013.02.012.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.