Emergency stent-graft implantation for iatrogenic peripheral arterial rupture.

Xiao L, Shen J, Tong J-J

СтатьяПеревод в очереди

Аннотация

PURPOSE: We evaluated the experience with and efficacy of stent-grafting for iatrogenic peripheral arterial ruptures.

MATERIALS AND

METHODS

From 2005 to 2009 we performed stent-grafting on four male patients (age 38-67 years) with iatrogenic peripheral arterial ruptures. In patient 1, grointissue necrosis followed a subcutaneous injection and led to femoral arterial rupture. Pseudoaneurysms ruptured in patients 2 and 3 who were undergoing femoral arteriotomy. Patient 1 experienced a ruptured carotid artery during neck surgery. Shock occurred in three of the four patients. Four patients underwent self-expanding stent-grafting (8 mm×60 mm or 8 mm×80 mm) under local anaesthesia.

RESULTS

Haemorrhages were controlled in all patients. No procedure-related complications occurred. Patient 1 died of lung metastases 13 months after stent-grafting. Follow-up examinations showed that the stent-graft remained patent in patients 1, 2 and 4, whereas stent occlusion occurred after 15 months in patient 3; in this case, a pseudoaneurysm proximal to the stent was identified, and although repeat stent-grafting successfully stopped the bleeding, the patient died of multiple organ failure 1 week later.

CONCLUSIONS

Emergency stent-grafting is a technically feasible and therapeutically effective modality for treating high-risk patients who experience iatrogenic peripheral arterial ruptures. The efficient treatment of hypotension and early endovascular intervention will improve the prognosis.

Для цитирования: Xiao L, Shen J, Tong J-J. Emergency stent-graft implantation for iatrogenic peripheral arterial rupture.. La Radiologia medica. 2012. DOI: 10.1007/s11547-012-0826-6.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.