MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.hlc.2026.05.007

Медицинская библиотека · Heart, lung & circulation · 2026

False-Positive Troponins: Clinical Misclassification, Delayed Recognition, and Health Care Costs in a Real-World Cohort.

Teng Lung En, Thomas Preetha, Quine Edward, Liaw Jacqueline, Place Amelia, Smith Joel, Taylor Andrew J, Fazio Timothy, Chiang Cherie, Koshy Anoop N

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Cardiac troponin immunoassays are critical for diagnosing myocardial infarction. Up to 10% of elevated results may be falsely positive because of heterophile antibodies or macrotroponin complexes, leading to misdiagnoses.

METHOD: We conducted a retrospective cohort study at the Royal Melbourne Hospital, Australia (January 2021-December 2024). The Abbott high-sensitivity troponin-I assay was the primary assay used in standard practice. Interference was confirmed according to institutional protocol when alternative assays (Ortho Vitros or Roche high-sensitivity assays) performed on the same plasma sample were negative. Clinical characteristics, investigations, treatment, documentation, and health care costs were reviewed.

RESULTS

Among 148,987 high-sensitivity troponin-I requests, 38 patients underwent alternate testing. In the 26 patients with confirmed interference, the median age was 48 years (interquartile range 36-60), with equal sex distribution; 39% had no cardiovascular risk factors. The median troponin levels were 150 ng/L. All underwent transthoracic echocardiography, and 73% received coronary imaging (computed tomography or invasive angiography). More than half had normal cardiac findings. Misdiagnoses included myocarditis (35%) and non-ST-elevation myocardial infarction (23%); 81% received treatment changes, including colchicine, aspirin, or anticoagulation. The median delay to recognition was 7.5 months. Documentation was inconsistent: only 54% had interference recorded in the medical record and 19% in discharge summaries. Estimated costs averaged AUD $16,331 per patient, largely because of avoidable admissions and procedures.

CONCLUSIONS

Troponin assay interference is an under-recognised source of false-positive troponin elevations, leading to diagnostic error, unnecessary testing, and substantial health care costs. Prompt recognition, consistent documentation, and routine confirmatory testing using alternate assays are essential to mitigate clinical and economic consequences.

Для цитирования: Teng Lung En, Thomas Preetha, Quine Edward, Liaw Jacqueline, Place Amelia, Smith Joel, Taylor Andrew J, Fazio Timothy, Chiang Cherie, Koshy Anoop N. False-Positive Troponins: Clinical Misclassification, Delayed Recognition, and Health Care Costs in a Real-World Cohort.. Heart, lung & circulation. 2026. DOI: 10.1016/j.hlc.2026.05.007.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.