m+Medelevator.RU
← Поиск публикаций
Breast cancer research : BCR · 2026

Intraoperative NIR-II fluorescence guidance for precise tumor margin assessment and maximized tissue preservation in breast surgery.

СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Zhang Yiyin, Li Ke, Zhang Shuwei, Yang Houpu, Wang Hailu, Chen Yiting, Feng Yenan, Chen Dingbao, Zhang Zeyu, Wang Shu

Аннотация

BACKGROUND: Accurate margin assessment remains a challenge in breast-conserving surgery, where inaccuracy leads to excessive removal and compromised aesthetics. Although second near-infrared (NIR-II) fluorescence imaging offers high contrast, there is still a lack of clinically viable NIR-II equipment.

METHODS: We develop an innovative NIR-II fluorescence navigation platform based on indocyanine green (ICG) that enables rapid deployment, operation-friendly workflow, and precision-at-hand capability for intraoperative guidance. Thirty-seven patients were recruited with 1 mg/kg ICG injection 45 minutes before surgery. Image quality was evaluated using perception-based image quality evaluator (PIQE) score, while quantitative analyses of fluorescence, including tumor-to-normal tissue ratio (TNR) and signal-to-background ratio (SBR), together with histopathology and a multi-level reader study, were performed to assess tumor contrast and diagnostic performance.

RESULTS: Compared to conventional NIR-I imaging, our NIR-II system demonstrates performance with enhanced spatial resolution and a higher tumor-to-normal tissue ratio (4.383 ± 1.719 versus 3.154 ± 1.072, P < 0.0001) in 37 patients. The intraoperative NIR-II imaging demonstrates superior tumor detection sensitivity [90.63% (75.78%-96.76%) vs. 84.38% (68.25%-93.14%)], with 100% diagnostic accuracy in delineating malignant tumor margins. Ex vivo NIR-II imaging enables real-time, precise visualization of tumor margins and suggested its potential to reduce the volume of excision. (NIR-II-defined volume < NIR-I-defined volume < current resection volume). Through brief training, surgeons can effectively utilize NIR-II imaging, shortening the learning curve for young surgeons in tumor and margin assessment.

CONCLUSION: This study demonstrates a clinically adaptable NIR-II imaging platform that expands intraoperative visualization without changing surgical workflow or adding operational burden, supporting standardized margin assessment and improved tissue preservation in breast surgery.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты