MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/jvim.14625

Медицинская библиотека · Journal of veterinary internal medicine · 2016

Blood Pressure Measurements in 780 Apparently Healthy Cats.

Payne J R, Brodbelt D C, Luis Fuentes V

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Mean systolic blood pressure in apparently healthy cats has been reported as approximately 125 mmHg using direct assessment, but there is greater variability in reported values using indirect assessment. Increasing age and the white-coat effect are associated with increased systolic blood pressure.

HYPOTHESIS/

OBJECTIVES

To report Doppler-derived blood pressure measurements from a large population of apparently healthy cats and to assess epidemiologic factors associated with recorded blood pressures.

ANIMALS: A total of 780 cats in rehoming centers enrolled in a screening program for heart murmurs and cardiac disease.

METHODS

Cats were considered healthy based on history and physical examination. Cats with known hypertension, hyperthyroidism, or clinical signs of systemic disease and pregnant or nursing queens were excluded. After an acclimatization period, systolic blood pressure was measured using the Doppler sphygmomanometry method following the recommendations of the ACVIM Consensus Statement. General linear model analysis was performed to identify factors associated with variation in systolic blood pressure.

RESULTS

Median (interquartile range, IQR) systolic blood pressure for the group was 120.6 (110.4-132.4) mmHg. Factors significantly associated with higher systolic blood pressure in a general linear model were increased age, increased nervousness, male sex, neutering, or history of being a stray. The model explained 29.2% of the variation in systolic blood pressure.

CONCLUSIONS AND CLINICAL

IMPORTANCE

The age, demeanor, sex, neuter status and history of being a stray should be taken into account when assessing systolic blood pressure in apparently healthy cats.

Для цитирования: Payne J R, Brodbelt D C, Luis Fuentes V. Blood Pressure Measurements in 780 Apparently Healthy Cats.. Journal of veterinary internal medicine. 2016. DOI: 10.1111/jvim.14625.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.