Initial safety outcomes for the Rigicon Infla10® inflatable penile prosthesis.

Wilson Steven K, Wen Lexiaochuan, Rossello Mariano, Maria Pedro, Carrion Rafael, Perito Paul, Ralph David, Antonini Gabriele, Carvajal Alejandro, Ozturk Metin I, Chung Eric

СтатьяПеревод в очереди

Аннотация

OBJECTIVE

To analyse data from patient information forms (PIFs) submitted to the manufacturer of a new three-piece inflatable penile prosthesis (IPP), the Rigicon Infla10®, to summarize early outcomes.

METHODS

A retrospective review of PIFs from 319 patients implanted with the IPP between 6 January 2019 and 31 December 2021 was performed to assess device durability and rates of reoperation for infection, mechanical failure or medical reasons.

RESULTS

The mean ± sd (range) follow-up was 21.2 ± 11 (5-36) months and the mean ± sd patient age was 58.5 ± 8.7 years. Of the total, 4.4% of devices required removal or revision. Complications included mechanical failure (2.5%) and component migration (0.7%). No infections were observed in this series. One patient (0.4%) required revision for inadequate straightening of Peyronie's disease. Three patients (0.9%) requested device removal because of dissatisfaction. A total of 95.6% of the Rigicon Infla10 devices were free from explant or revision 21 months after the original implant date. Kaplan-Meier analysis showed the rates of cumulative survival of the device at 12, 24, 36 months were 95.6%, 94.7% and 93.7%, respectively.

CONCLUSIONS

The vast majority of the early Rigicon Infla10 IPPs implanted prior to January 2022 were included in this retrospective analysis of volunteered PIFs. These early results demonstrate initial durability from reoperation equivalent to that of other contemporary devices.

Для цитирования: Wilson Steven K, Wen Lexiaochuan, Rossello Mariano, Maria Pedro, Carrion Rafael, Perito Paul, Ralph David, Antonini Gabriele, Carvajal Alejandro, Ozturk Metin I, Chung Eric. Initial safety outcomes for the Rigicon Infla10® inflatable penile prosthesis.. BJU international. 2023. DOI: 10.1111/bju.15960.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.