MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/icl.0000000000000376

Медицинская библиотека · Eye & contact lens · 2018

Estrogen- and Progesterone-Induced Variation in Corneal Parameters According to Hormonal Status.

Bahadir Kilavuzoglu Ayse Ebru, Cosar Cemile Banu, Bildirici Ibrahim, Cetin Omer, Ozbasli Esra

СтатьяПеревод в очереди

Аннотация

OBJECTIVES

To determine the effects of estrogen and progesterone on corneal thickness, curvature, and biomechanics in healthy corneas according to hormonal status.

METHODS

The study included four groups of females: group A (menstruating, not pregnant, not lactating, and not menopausal; n=100), group B (pregnant; n=50), group C (lactating; n=50), and group D (menopausal; n=50). Group A was subdivided according to age, as subgroup A15-25 (age 15-25 years) and subgroup A>25 (age >25 years). Blood estradiol and progesterone levels were measured in each participant. All the participants underwent a full ophthalmologic examination, including corneal thickness and corneal topography measurement, and evaluation of corneal biomechanical properties.

RESULTS

The corneal resistance factor and anterior corneal flat keratometry values were significantly higher in group D (P=0.040 and P=0.026, respectively) than in the other three groups. Posterior corneal steep keratometry values were significantly higher in subgroup A>25 during the preovulatory phase than ovulatory and postovulatory phases (P=0.012). In group B, there was a significant negative correlation between gestational week and intraocular pressure (IOP) (r=-0.322, P=0.024). Corneal volume was significantly higher during the early postpartum period than the late postpartum period in group C (P=0.028). Intraocular pressure, Goldman-correlated IOP, and corneal-compensated IOP differed significantly between the groups (P<0.05).

CONCLUSIONS

Blood levels of estrogen and progesterone were associated with variations in IOP, but estrogen and progesterone did not have a consistent effect on topographic parameters or biomechanical properties in healthy corneas.

Для цитирования: Bahadir Kilavuzoglu Ayse Ebru, Cosar Cemile Banu, Bildirici Ibrahim, Cetin Omer, Ozbasli Esra. Estrogen- and Progesterone-Induced Variation in Corneal Parameters According to Hormonal Status.. Eye & contact lens. 2018. DOI: 10.1097/icl.0000000000000376.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.