DOI 10.1016/j.gie.2011.12.014

Медицинская библиотека · Gastrointestinal endoscopy · 2012

Evaluation of GI bleeding after implantation of left ventricular assist device.

Kushnir Vladimir M, Sharma Shivak, Ewald Gregory A, Seccombe Jonathan, Novak Eric, Wang I-Wen, Joseph Susan M, Gyawali C Prakash

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Left ventricular assist devices (LVADs) have revolutionized the management of end-stage heart failure (ESHF). However, unexpectedly high rates of GI bleeding (GIB) have been described, and etiology and outcome remain unclear.

OBJECTIVE

To determine the prevalence, etiology, and outcome of GIB in LVAD recipients.

DESIGN

Retrospective case series.

SETTING

Tertiary care academic university hospital.

PATIENTS: 154 ESHF patients (55.4 years, 122 men/32 women) with LVADs implanted over a 10-year period.

MAIN OUTCOME MEASUREMENTS: Overt or occult GIB prompting endoscopic evaluation ≥ 7 days after LVAD implantation.

RESULTS

Over a mean of 0.9 ± 0.1 years of follow-up, 29 patients (19%) experienced 44 GIB episodes. Patients with GIB were older and received anticoagulation therapy before devices were implanted (P ≤ .02 for each). GIB was overt (n = 31) rather than occult (n = 13), and most patients presented with melena (n = 22, 50%); hemodynamic instability was observed in 13.6%. Each bleeding episode required 2.1 ± 0.1 diagnostic or therapeutic procedures, and a source was localized in 71%. Upper endoscopy provided the highest diagnostic yield; peptic bleeding (n = 14) and vascular malformations (n = 8) dominated the findings. Endoscopy was safe and well tolerated. Overall mortality was 35%, none directly from GIB.

LIMITATION: Retrospective design.

CONCLUSIONS

Rates of GIB with LVADs are higher than that seen in other patient populations, including those receiving anticoagulation and antiplatelet therapy. GIB episodes are mostly overt and predominantly from the upper GI tract. Endoscopy is safe in the LVAD population.

Для цитирования: Kushnir Vladimir M, Sharma Shivak, Ewald Gregory A, Seccombe Jonathan, Novak Eric, Wang I-Wen, Joseph Susan M, Gyawali C Prakash. Evaluation of GI bleeding after implantation of left ventricular assist device.. Gastrointestinal endoscopy. 2012. DOI: 10.1016/j.gie.2011.12.014.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.