MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1109/10.376129

Медицинская библиотека · IEEE transactions on bio-medical engineering · 1995

Distribution of aortic mechanical prosthetic valve closure sound model parameters on the surface of the chest.

Baykal A, Ider Y Z, Köymen H

СтатьяПеревод в очереди

Аннотация

It has been previously proposed that heart valve closure sounds can be modeled by a sum of decaying sinusoids, based on the hypothesis that the heart cavity, heart walls, major vessels, and other structures in the chest constitute a frequency selective linear acoustic system and this system is excited by the rapidly decelerating valve occluder. In this study, distribution of the parameters of this model for the second heart sound is investigated. For this purpose, heart sounds of 10 patients who have a St. Jude-type bileaflet mechanical heart valve prosthesis in aortic position are recorded. Recordings are performed at 12 different locations on the surface of the chest. To reliably assign representative parameters to each recording site, signal averaging, model order selection, and a special filtration technique are employed. The results of the analyses are discussed in relation to the above hypothesis on the heart sound generation mechanism. It is observed that site-to-site variation of frequencies of modes does not exceed the accuracy limit of proposed analysis method, but energies of these modes vary on the surface of the chest, and as a result of statistical analysis, it appears that energy of some modes are significantly different between two recording sites.

Для цитирования: Baykal A, Ider Y Z, Köymen H. Distribution of aortic mechanical prosthetic valve closure sound model parameters on the surface of the chest.. IEEE transactions on bio-medical engineering. 1995. DOI: 10.1109/10.376129.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.