DOI 10.1016/j.knee.2022.01.006
Anterior cruciate ligament reconstruction with ultrasound-guided femoral nerve block does not adversely affect knee extensor strength beyond that seen with intravenous patient-controlled analgesia at 3 and 6 months postoperatively.
Аннотация
BACKGROUND
This study aimed to investigate the effect of anterior cruciate ligament (ACL) reconstruction with an ultrasound-guided femoral nerve block (FNB) on knee extensor strength weakness 3 and 6 months, and graft rupture in the 1 year following ACL reconstruction.
METHODS
One hundred and seven patients who underwent ACL reconstruction were included in this retrospective study. The patients were divided into two groups stratified by the method of postoperative pain management. The FNB group included 66 patients, and there were 41 patients in the intravenous patient-controlled analgesia (iv-PCA) group. The isokinetic peak torque of knee flexor and extensor was measured preoperative, 3 and 6 months after ACL reconstruction. Muscle strength measurements were performed using the BIODEX dynamometer at a velocity of 60°/s and 180°/s. Peak torque of knee extensor and flexor strength, estimated pre-injury capacity (EPIC), body weight ratio (BW), and graft rupture incidence were compared between the two groups.
RESULTS
There were no statistically significant differences in the knee extensor and flexor strength for all items at 3 and 6 months after ACL reconstruction. There was also not a statistically significant difference in the graft rupture incidence between the two groups: FNB group was two patients, 3.0% vs. iv-PCA group was one patient, 2.4% (p = 0.86).
CONCLUSION
ACL reconstruction with ultrasound-guided FNB does not affect knee extensor strength at 6 months, nor graft rupture at 1 year postoperatively.