MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1080/09553002.2016.1234725

Медицинская библиотека · International journal of radiation biology · 2016

Dose assessment intercomparisons within the RENEB network using G0-lymphocyte prematurely condensed chromosomes (PCC assay).

Terzoudi Georgia I, Pantelias Gabriel, Darroudi Firouz, Barszczewska Katarzyna, Buraczewska Iwona, Depuydt Julie, Georgieva Dimka, Hadjidekova Valeria, Hatzi Vasiliki I, Karachristou Ioanna, Karakosta Maria, Meschini Roberta, M'Kacher Radhia, Montoro Alegria, Palitti Fabrizio, Pantelias Antonio, Pepe Gaetano, Ricoul Michelle, Sabatier Laure, Sebastià Natividad, Sommer Sylwester, Vral Anne, Zafiropoulos Demetre, Wojcik Andrzej

Сравнительное исследованиеОценочное исследованиеСтатьяВалидационное исследованиеПеревод в очереди

Аннотация

PURPOSE: Dose assessment intercomparisons within the RENEB network were performed for triage biodosimetry analyzing G0-lymphocyte PCC for harmonization, standardization and optimization of the PCC assay.

MATERIALS AND

METHODS

Comparative analysis among different partners for dose assessment included shipment of PCC-slides and captured images to construct dose-response curves for up to 6 Gy γ-rays. Accident simulation exercises were performed to assess the suitability of the PCC assay by detecting speed of analysis and minimum number of cells required for categorization of potentially exposed individuals.

RESULTS

Calibration data based on Giemsa-stained fragments in excess of 46 PCC were obtained by different partners using galleries of PCC images for each dose-point. Mean values derived from all scores yielded a linear dose-response with approximately 4 excess-fragments/cell/Gy. To unify scoring criteria, exercises were carried out using coded PCC-slides and/or coded irradiated blood samples. Analysis of samples received 24 h post-exposure was successfully performed using Giemsa staining (1 excess-fragment/cell/Gy) or centromere/telomere FISH-staining for dicentrics.

CONCLUSIONS

Dose assessments by RENEB partners using appropriate calibration curves were mostly in good agreement. The PCC assay is quick and reliable for whole- or partial-body triage biodosimetry by scoring excess-fragments or dicentrics in G0-lymphocytes. Particularly, analysis of Giemsa-stained excess PCC-fragments is simple, inexpensive and its automation could increase throughput and scoring objectivity of the PCC assay.

Для цитирования: Terzoudi Georgia I, Pantelias Gabriel, Darroudi Firouz, Barszczewska Katarzyna, Buraczewska Iwona, Depuydt Julie, Georgieva Dimka, Hadjidekova Valeria, Hatzi Vasiliki I, Karachristou Ioanna, Karakosta Maria, Meschini Roberta, M'Kacher Radhia, Montoro Alegria, Palitti Fabrizio, Pantelias Antonio, Pepe Gaetano, Ricoul Michelle, Sabatier Laure, Sebastià Natividad, Sommer Sylwester, Vral Anne, Zafiropoulos Demetre, Wojcik Andrzej. Dose assessment intercomparisons within the RENEB network using G0-lymphocyte prematurely condensed chromosomes (PCC assay).. International journal of radiation biology. 2016. DOI: 10.1080/09553002.2016.1234725.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.