MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/j.1432-2277.2005.00196.x

Медицинская библиотека · Transplant international : official journal of the European Society for Organ Transplantation · 2005

Preoperative evaluation of living kidney donors using multirow detector computed tomography: comparison with digital subtraction angiography and intraoperative findings.

Hänninen Enrique Lopez, Denecke Timm, Stelter Lars, Pech Maciej, Podrabsky Petr, Pratschke Johann, Ricke Jens, Schindler Ralf, Neuhaus Peter, Felix Ronald, Tullius Stefan G

СтатьяПеревод в очереди

Аннотация

To assess the accuracy of multirow detector computed tomography (MDCT) for the evaluation of renal anatomy for preoperative donor assessment in living related kidney transplantation. MDCT-scans (4- and 16-slice-CT) of 51 consecutive living kidney donors (age, 51.6 +/- 9.7 years; range, 28-68 years) were analysed by three blinded observers and compared with digital subtraction angiography (DSA) and surgery. Contrast-enhanced MDCT was performed with 1 mm slice thickness reconstruction interval during arterial and venous phases. Supernumerary renal arteries, veins, early branching of vessels and abnormalities of the ureters were documented. The overall accuracy of computed tomography angiography (CTA) for detection and classification of surgically relevant arterial variants was 97% (99/102). The interpretation of 16-channel MDCT images was correct in all cases (accuracy, 100%), while the four-channel CTA had three incorrect results regarding the differentiation of early branching vessels from double renal arteries (accuracy, 93%). The overall accuracy of DSA was 91%. Renal vein abnormalities were correctly diagnosed with MDCT in 100% compared with 89% correct findings with DSA. There were three kidneys with incomplete ureter duplication, detected both with MDCT and DSA. MDCT demonstrated superior accuracy compared with non-selective DSA for the preoperative assessment of renal anatomy in living kidney donors; and for the distinction of supernumerary arteries versus early branching patterns, 16-channel CTA data were better than those of the four-channel system.

Для цитирования: Hänninen Enrique Lopez, Denecke Timm, Stelter Lars, Pech Maciej, Podrabsky Petr, Pratschke Johann, Ricke Jens, Schindler Ralf, Neuhaus Peter, Felix Ronald, Tullius Stefan G. Preoperative evaluation of living kidney donors using multirow detector computed tomography: comparison with digital subtraction angiography and intraoperative findings.. Transplant international : official journal of the European Society for Organ Transplantation. 2005. DOI: 10.1111/j.1432-2277.2005.00196.x.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.