MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.acvd.2019.05.004

Медицинская библиотека · Archives of cardiovascular diseases · 2019

Long-term outcome of heart transplantation performed after ventricular assist device compared with standard heart transplantation.

Petroni Thibaut, D'Alessandro Cosimo, Combes Alain, Golmard Jean-Louis, Brechot Nicolas, Barreda Eleodoro, Laali Mojgan, Farahmand Patrick, Varnous Shaida, Weber Pascale, Pavie Alain, Leprince Pascal

Сравнительное исследованиеСтатьяНаблюдательное исследованиеПеревод в очереди

Аннотация

BACKGROUND

Data on the long-term outcome of heart transplantation in patients with a ventricular assist device (VAD) are scarce.

AIM: To evaluate long-term outcome after heart transplantation in patients with a VAD compared with no mechanical circulatory support.

METHODS

Consecutive all-comers who underwent heart transplantation were included at a single high-volume centre from January 2005 until December 2012, with 5 years of follow-up. Clinical and biological characteristics, operative results, outcomes and survival were recorded. Regression analyses were performed to determine predictors of 1-year and 5-year mortality.

RESULTS

Fifty-two patients with bridge to transplantation by VAD (VAD group) and 289 patients transplanted without a VAD (standard group) were enrolled. The mean age was 46±11 years in the VAD group compared with 51±13 years in the standard group (P=0.01); 17% of the VAD group and 25% of the standard group were women (P=0.21). Ischaemic time was longer in the VAD group (207±54 vs 169±60minutes; P<0.01). There was no difference in primary graft failure (33% vs 25%; P=0.22) or 1-year mortality (17% vs 28%; P=0.12). In the multivariable analysis, preoperative VAD was an independent protective factor for 1-year mortality (odds ratio 0.40, 95% confidence interval 0.17-0.97; P=0.04). Independent risk factors for 1-year mortality were recipient age>60 years, recipient creatinine, body surface area mismatch and ischaemic time. The VAD and standard groups had similar long-term survival, with 5-year mortality rates of 35% and 40%, respectively (P=0.72).

CONCLUSIONS

Bridge to transplantation by VAD was associated with a reduction in 1-year mortality, leading critically ill patients to similar long-term survival compared with patients who underwent standard heart transplantation. This alternative strategy may benefit carefully selected patients.

Для цитирования: Petroni Thibaut, D'Alessandro Cosimo, Combes Alain, Golmard Jean-Louis, Brechot Nicolas, Barreda Eleodoro, Laali Mojgan, Farahmand Patrick, Varnous Shaida, Weber Pascale, Pavie Alain, Leprince Pascal. Long-term outcome of heart transplantation performed after ventricular assist device compared with standard heart transplantation.. Archives of cardiovascular diseases. 2019. DOI: 10.1016/j.acvd.2019.05.004.