BACKGROUND

High-intensity focused ultrasound (HIFU) is a minimally invasive treatment option for selected patients with localized prostate cancer. This article is not intended as an original outcome study but as a practice-oriented expert review and institutional experience report on focal and hemiablative HIFU.

MATERIAL AND

METHODS

We describe patient selection, preoperative diagnostic assessment and biopsy mapping, intraoperative planning, safety margins, HIFU ablation using EDAP/Focal One(R), the double tap strategy, documentation and follow-up. Institutional practice is explicitly distinguished from evidence-based standards and consensus recommendations.

RESULTS

Reproducible outcomes require concordance between imaging and histological findings, an adequate safety margin around the index lesion, structured intraoperative documentation and a follow-up strategy including PSA kinetics, mpMRI and biopsy when indicated. The double tap strategy is presented as an institutionally established technical modification, with a brief summary of the available group data.

CONCLUSION

HIFU can be performed safely when carried out in a standardized manner. Treatment quality depends substantially on patient selection, treatment planning, technical execution, and post-treatment follow-up.

Для цитирования: Salomon Georg, Heckmann Neele, Hohenhorst Jan Lukas, Ekrutt Jonas, Palec Jan, Nagaraj Yamini. [HIFU: Best Practices for Optimal Performance].. Aktuelle Urologie. 2026. DOI: 10.1055/a-2919-7470.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.