Background
Legionnaires' disease is a potentially lethal pneumonia contracted through inhalation of aerosolized water contaminated with Legionella bacteria. Detection and control of L. pneumophila, the primary species responsible for the disease, is critical to public health. In Québec, cooling towers and evaporative condensers are required to follow a maintenance and testing program to ensure L. pneumophila concentrations remain at acceptable levels.
Objective
This study compared a new culture method based on the most probable number approach, Legiolert®, with the formal culture method used at EnvironeX for regulatory compliance testing to quantify L. pneumophila from cooling tower waters in Québec.
Methods
A split-sample analysis was performed in which 401 samples from cooling towers in Québec were tested with both methods.
Results
Results with 74 positive samples showed that Legiolert provided a significant increase in sensitivity for L. pneumophila compared with the agar plate method. Cooling tower samples often contain non-Legionella flora that necessitate multiple treatment and plating conditions to prevent interference with the test. Legiolert showed little to no impact from non-Legionella organisms in this study.
Conclusions
Overall, Legiolert showed several advantages over the agar plate method, including increased sensitivity, reduced interference, a simplified test procedure, and an easy-to-read positive signal.