MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1038/s41598-025-26717-3

Медицинская библиотека · Scientific reports · 2025

Dual-responsive bis-Schiff base fluorescent probe for simultaneous detection of Zn2+ and HClO in environmental monitoring and information encryption.

Yang Fan, Ma Yinglong, Zou Hanxun, Liu Yang, Li Xiaopei, Huang Jing

СтатьяПеревод в очереди

Аннотация

The dysregulation of zinc ions (Zn2+) and hypochlorous acid (HClO) poses significant threats to ecological systems and human health. Consequently, the development of robust analytical tools for the detection of these ions is imperative. While numerous fluorescent probes exist for individual analytes, the creation of single-molecule platforms for dual detection remains a formidable challenge. In this study, we reported a novel bis-Schiff base fluorescent probe (P-B) for the simultaneous and distinct detection of Zn2+ and HClO. In the presence of Zn2+, the probe displays a substantial “turn-on” fluorescence response at 520 nm with high selectivity, rapid response time (< 60 s) and exceptionally low detection limit of 17.50 nM. In contrast, P-B functions as a “turn-off” sensor for HClO, enabling selective detection with a limit of 0.24 µM. The practical utility of P-B was successfully validated in real-world applications. The instrument was utilized for the on-site, visual screening of Zn2+ contamination in soil samples and for quantitative detection in environmental water. Furthermore, the unique “invisible-to-visible” fluorescence transformation of the compound upon binding with Zn2+ was ingeniously leveraged to develop an advanced information encryption system. This simple, robust, versatile molecular tool holds significant promise for environmental monitoring and information security applications.

Для цитирования: Yang Fan, Ma Yinglong, Zou Hanxun, Liu Yang, Li Xiaopei, Huang Jing. Dual-responsive bis-Schiff base fluorescent probe for simultaneous detection of Zn2+ and HClO in environmental monitoring and information encryption.. Scientific reports. 2025. DOI: 10.1038/s41598-025-26717-3.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.