MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00402-018-3089-4

Медицинская библиотека · Archives of orthopaedic and trauma surgery · 2018

Prevention of postoperative bleeding in hip fractures treated with prosthetic replacement: efficacy and safety of fibrin sealant and tranexamic acid. A randomised controlled clinical trial (TRANEXFER study).

Jordan Marcos, Aguilera Xavier, González José Carlos, Castillón Pablo, Salomó Mónica, Hernández José Antonio, Ruiz Leonardo, Mora José Maria, Camacho-Carrasco Pilar, Prat-Fabregat Salvi, Bosch Alba, Rodriguez-Arias Ainhoa, Martínez-Zapata María José, TRANEXFER Group

СтатьяМногоцентровое исследованиеРандомизированное исследованиеПеревод в очереди

Аннотация

INTRODUCTION

We assessed the efficacy of fibrin sealant (FS) and tranexamic acid (TXA) administered topically in patients with a hip fracture treated with prosthetic replacement.

MATERIALS AND

METHODS

Parallel, multicentre, open label, randomised, clinical trial. We compared three interventions to reduce blood loss: (1) 10 ml of FS, (2) 1 g of topical TXA, both administered at the end of the surgery, and (3) usual haemostasis (control group). The main outcome was blood loss collected in drains. Other secondary variables were total blood loss, hidden blood loss, transfusion rate, average hospital stay, complications, adverse events, and mortality.

RESULTS

A total of 158 patients were included, 56 in the FS group, 52 in the TXA group, and 50 in the control group. The total amount of blood collected in drains was lower in the TXA group (148.6 ml, SD 122.7 in TXA; 168.2 ml, SD 137.4 in FS; and 201.5 ml, SD 166.5 in control group) without achieving statistical significance (p = 0.178). The transfusion rate was lower in the TXA group (32.7%), compared with FS group (42.9%) and control group (44.0%), without statistical significance (p = 0.341). There were no complications or adverse effects related to the evaluated interventions.

CONCLUSIONS

The use of TXA and FS administered topically prior to surgical closure in patients with a sub-capital femoral fracture undergoing arthroplasty did not significantly reduce either postoperative blood loss or transfusion rate, compared with a group that only received usual haemostasis.

Для цитирования: Jordan Marcos, Aguilera Xavier, González José Carlos, Castillón Pablo, Salomó Mónica, Hernández José Antonio, Ruiz Leonardo, Mora José Maria, Camacho-Carrasco Pilar, Prat-Fabregat Salvi, Bosch Alba, Rodriguez-Arias Ainhoa, Martínez-Zapata María José, TRANEXFER Group. Prevention of postoperative bleeding in hip fractures treated with prosthetic replacement: efficacy and safety of fibrin sealant and tranexamic acid. A randomised controlled clinical trial (TRANEXFER study).. Archives of orthopaedic and trauma surgery. 2018. DOI: 10.1007/s00402-018-3089-4.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.